Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
Search Results "Detectable Warning"
Commonly Searched Documents
-
11B-705.1.1.2 Dome spacing
- SafetyStepTD Powerbond Detectable Warning Mat
-
4.29.3* TACTILE WARNINGS ON DOORS TO HAZARDOUS AREAS
Doors that lead to areas that might prove dangerous to a blind person (for example, doors to loading platforms, boiler rooms, stages, and the like) shall be made identifiable to the...
-
A4.29.3 TACTILE WARNINGS ON DOORS TO HAZARDOUS AREAS
Tactile signals for hand reception are useful if it is certain that the signals will be touched.
- Detectable Warning Systems, Inc. EZ Set Tile™
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1....
- SafetyStepTD Ramp-Up Detectable Warning System Video
-
Platform Edges: ADA Standard Section 705.2
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
- Detectable Warning Systems, Inc. AlertCast® Cast-in-Place Detectable Warning installation Video
-
Contrast
Detectable warnings are required to contrast visually from adjacent walking surfaces, either light-on dark or dark-on-light....
-
11B-705.1.1.3.2
11B-705.1.1.3.2 Detectable warning surfaces shall provide a 70 percent minimum visual contrast with adjacent walking surfaces....
-
11B-705.1.1.3.2
Detectable warning surfaces shall provide a 70 percent minimum visual contrast with adjacent walking surfaces....
-
11B-705.3 Product Approval
Only approved DSA-AC detectable warning products and directional surfaces shall be installed as provided in the California Code of Regulations (CCR), Title 24, Part 1, Chapter 5, Articles...
-
11B-705.3 Product Approval
Only approved DSA-AC detectable warning products and directional surfaces shall be installed as provided in the California Code of Regulations (CCR), Title 24, Part 1, Chapter 5, Articles...
-
11B-705.3 Product Approval
Only approved DSA-AC detectable warning products and directional surfaces shall be installed as provided in the California Code of Regulations (CCR), Title 24, Part 1, Chapter 5, Articles...
-
Costs to Provide Detectable Warning Surfaces on Curb Ramps (Section-by-Section Analysis)
Costs to Provide Detectable Warning Surfaces on Curb Ramps (Section-by-Section Analysis) Detectable warning surfaces are available in a variety of materials....
- Detectable Warning Systems, Inc. EZ Set Tile™ heavy duty replaceable cast-in-place detectable warning
-
4.29.1 GENERAL
Tactile warnings required to be accessible by 4.1 shall comply with 4.29....
-
4.1.2(14)
(14) Tactile warnings shall be provided at hazardous conditions as specified in 4.29.3....
-
4.29.7* STANDARDIZATION
Textured surfaces for tactile door warnings shall be standard within a building, facility, site, or complex of buildings....
-
A4.29.7 STANDARDIZATION
Too many tactile warnings or lack of standardization weakens their usefulness....
-
Detectable warnings on curb ramps
Curb ramps must have detectable warnings. (DOT ADA Standard 406.8.)...
-
705.1.3 Contrast
Detectable warning surfaces shall contrast visually with adjacent walking surfaces either light-on-dark, or dark-on-light....