The proposed rule included a requirement for visual alarms in employee work areas that are served by audible alarms (203.3)....
Search Results "Carbon Monoxide Alarm"
Commonly Searched Documents
-
Visual Alarms
-
[F] 907.5.2.3 Visible alarms
[F] 907.5.2.3 Visible alarms. Visible alarm notification appliances shall be provided in accordance with Sections 907.5.2.3.1 through 907.5.2.3.5. Exceptions: 1. ...
-
[F] 907.5.2.3 Visible alarms
Exceptions: In other than Group I-2 and I-2.1, visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced...
-
Sensory Impairments
Sensory Impairments: Employers should install lighted fire strobes and other visual or vibrating alerting devices to supplement audible alarms....
-
[F] 907.5.2 Alarm notification appliances
...
-
215 Fire Alarm Systems
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with 702 can be integrated into the alarm system....
-
4.28.1 GENERAL
Alarm systems required to be accessible by 4.1 shall comply with 4.28....
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.2 can be integrated into the...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
F215.3 Employee Work Areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with 702 can be integrated into the alarm system....
-
215.3 Employee Work Areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with 702 can be integrated into the alarm system....
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
215.3 Employee Work Areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with 702 can be integrated into the alarm system....
-
4.28.3(8)
(8) No place in common corridors or hallways in which visual alarm signalling appliances are required shall be more than 50 ft (15 m) from the signal....
-
[F] 907.5.2.3.3 Groups R-1 and R-2.1
Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.3 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke...
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.2 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke...
-
[F] 907.4.2 Manual fire alarm boxes
...
-
4.28.1 General
Alarm systems required to be accessible by 4.1 shall comply with 4.28....
-
Interconnection: ADA Standard Section 809.5.3
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
-
Prohibited Use: ADA Standard Section 809.5.4
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
Scoping [4.1.3(14)]
Scoping [4.1.3(14)] ADAAG requires both audible and visual alarms in facilities that have emergency warning systems whether building-wide systems or self-contained units are provided....
-
F215 Fire Alarm Systems
[See subsections ...]
-
215 Fire Alarm Systems
[See subsections ...]