.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch?...
Search Results "Transfer Wall"
Commonly Searched Documents
-
H1
-
4.30.6 Mounting Location and Height
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
Subjects
Subjects The target sample required wheeled mobility device users who lived in the community and were able to transfer independently (with or without a transfer board) and who represent...
-
8.4 Improving Data Sources and Research
It is not clear what size surface is truly needed for individuals to transfer comfortably....
-
711.3.2 Membrane penetrations
Where walls and partitions are required to have a minimum 1-hour fire-resistance rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced....
-
Maneuvering Clearances at Doors [4.13.6]
Clearance to the wall plane next to the door (even when the door is in a recess) is essential....
-
Side guard protocol
Of the 60 subjects that were able to transfer to a higher level than their own WMD, 98% (59/60), CI[91%,99%] were able to transfer to height of 22” (55.9cm) (Figure 12 and Table 8)....
-
Adjustable gap protocol
One hundred and fourteen (114) subjects were tested under this protocol and six could not transfer with a gap of any size added between their WMD and the platform in the configuration shown...
-
Temporary and Permanent Structures: ADA Standard Section 201.3
Section 201.3 covers the application of the most current requirements for temporary and permanent structures.
-
11B-407.4.10 Support rail
Support rails shall be provided on at least one wall of the car. Advisory 11B-407.4.10 Support rail....
-
704.8 Allowable area of openings
Values given are percentage of the area of the exterior wall. b....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
Bathrooms
Some rooms in larger facilities must have a combination roll-in/ transfer shower....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position; M302 Diagnostic Equipment Used by Patients in Seated Position
The purpose of these sections is to facilitate independent transfer onto and off of diagnostic equipment by patients with disabilities, including those who use mobility devices or aids,...
-
H22
Is a second horizontal grab bar at least 36 inches long securely mounted on the back wall with one end no more than 6 inches from the side wall 33 to 36 inches above the floor?...
-
M19
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall?...
-
4.3.5.2 180-degree turn
Our research findings for this turn apply to corridors and other circulation spaces are bounded by two parallel walls or three walls....
-
11B-216.12 Amusement rides
Amusement rides designed primarily for children, amusement rides that are controlled or operated by the rider, and amusement rides without seats, are not required to provide wheelchair spaces, transfer...
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn
These data are based on measurements of wheeled mobility users performing 180-degree turns in a dead-end hallway, built with mock walls....
-
§382.65(c)(1)
1) On-board wheelchairs must include footrests, armrests which are movable or removable, adequate occupant restraint systems, a backrest height that permits assistance to passengers in transferring...
-
3.3.1 Research Data
The Committee also considered findings from University of Pittsburgh study that looked at transfers, specifically at how different conditions affected the abilities of WMD users to transfer...
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...