M303.2.4.2 Knee Clearance
Between 9 inches (230 mm) and 27 inches (685 mm) above the floor, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for every 6 inches (150 mm) in height...
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position; M302 Diagnostic Equipment Used by Patients in Seated Position
technical criteria for diagnostic equipment used by patients in a supine, prone, or sidelying position, and M302 provides technical criteria for diagnostic equipment used by patients in a seated...
-
TICKETING
the same times and in the same ways as the purchase of other tickets; Accessible seating must be identified to the same level of specificity as other seats on maps, seating charts...
-
Stadium-style theaters. (Section-by-Section Analysis)
Lines of sight and dispersal of wheelchair seating in assembly areas, especially in stadium-style theaters, have been the subject of litigation. ...
-
M303.2.3 Depth (Section-by-Section Analysis)
Access Board clarifies that this provision is not a clear space requirement for wheelchair approach, but is instead the wheelchair space integral to diagnostic equipment for a patient seated...
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
M305.2.2 Length (Section-by-Section Analysis)
In the MDE NPRM there was no requirement for length of the transfer support; however, the MDE NPRM preamble noted that the Access Board was considering requiring the transfer...
-
5.7 Lift Compatibility
5.7 Lift Compatibility.
-
5.7 Lift Compatibility Recommendations
5.7 Lift Compatibility Recommendations
-
M303.3.3.1 Running Slope
EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches (64 mm)....
-
Signage Requirements in the 2010 Standards for Accessible Design
The purpose of the SEGD 2012 ADA White Paper Update is to help the EGD community meet the spirit and intent of the new SAD accessible guidelines.
-
Appendix 3 - Comparison of US Standards to IDEA Center Research
(HH) 915 80 895 754 1024 Armrest Height (AH) 760...
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform...
-
M303.2.1 Orientation (Section-by-Section Analysis)
The Board did not include requirements for patient body positioning because the diagnostic equipment cannot override the position in which an individual is seated in his or her wheelchair...
-
M305.2.1 Location (Section-by-Section Analysis)