1133B.5.4.5
Intermediate and bottom landings at a change of direction in excess of 30 degrees shall have a dimension in the direction of ramp run of not less than 72 inches (1829 mm) to accommodate...
-
Elevated Accessible Routes
clear width 32-inch (815 mm) narrowed width permitted for 24-inch (610 mm) length to accommodate features in the composite structure 12-inch (305 mm) rise maximum per ramp run...
-
Disorienting Spaces (slide 7)
It is all just sort of orangy, runs together, very disastrous design change. [In the photo] on the right, it looks like steps. It’s not....
-
Gratings [4.5.4]
Gaps or openings wider than ½ inch should be avoided or else treated, especially where they run parallel to a direction of travel....
- Allegion Von Duprin 94/95 Series INPACT Recessed Exit Device
-
Fares
Where bus and rail systems are run by the same provider (or where the same bus provider runs parallel local and express buses along the same route), the comparison would be made to the mode...
-
Recommendations for Future Research
• Additional research would be required to determine the validity and repeatability of the Rotational Penetrometer measurements on surfaces with slopes greater than 5%....
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2. [2010 ADAS] Advisory 303.3 Beveled.  ...
-
Thresholds at Doorways
The 1991 Standards and the 2010 Standards require raised thresholds that exceed ¼ inch in height to be beveled on each side with a slope not steeper than 1:2....
-
Clear Deck Space
Clear Deck Space Clear deck space of 60 by 60 inches minimum, with a slope of not more than 1:48, must be provided at the base of a transfer wall....
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space,head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
4(2)
(2) In single-story dwelling units, changes in level within the dwelling unit with heights between 1/4 inch and 1/2 inch are beveled with a slope no greater than 1:2....
-
303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
A. Accessible Entrance
Accessible Entrance Having a way to get into the emergency shelter on a surface that is firm, stable, slip resistant, without steps or steep slopes, and wide enough for a person using...
-
Outdoor Conditions [4.8.8]
A slope up to 2% is allowed at landings for adequate drainage....
-
4.4.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Electronic instruments
Originally created to measure the flatness of concrete floors in critical applications such as narrow - aisle warehouses, these devices can be used to measure slope flatness....
-
Three Additional Features for Van-Accessible Parking Spaces
accessible" and the international symbol of accessibility mounted high enough so the sign can be seen when a vehicle is parked in the space 96" min. width access aisle, level (max. slope...