Gangways A gangway is a variable-sloped pedestrian walkway linking a fixed structure or land with a floating structure....
Search Results "Running Slope"
Commonly Searched Documents
-
Gangways
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
§ 36.304(d)(3)
Such measures include, for example, providing a ramp with a steeper slope or widening a doorway to a narrower width than that mandated by the alterations requirements....
-
Verify Rough Plumbing
drain. 11B-607.5 Installation height and location of shower controls. 11B-608.5 Location of shower drains and floor slope...
-
R304.2.3 Flared Sides
Where a pedestrian circulation path crosses the curb ramp, flared sides shall be sloped 10 percent maximum, measured parallel to the curb line. Advisory R304.2.3 Flared Sides....
-
Thresholds at Doorways [4.13.8]
Thresholds above ¼ inch must be beveled with a slope no greater than 1:2....
-
Verify Rough Plumbing
drain. 11B-607.5 Installation height and location of shower controls. 11B-608.5 Location of shower drains and floor slope...
-
2) Where the Standard says "Changes in level are not permitted"
such as 304.2 for turning spaces: Here the standard is followed by an unenforceable advisory that says, "As used in this section, the phrase ‘changes in level’ refers to surfaces with slopes...
-
4.33.3* PLACEMENT OF WHEELCHAIR LOCATIONS
EXCEPTION: Accessible viewing positions may be clustered for bleachers, balconies, and other areas having sight lines that require slopes of greater than 5 percent....
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2....
-
11B-1005.1 Accessible routes
length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section 11B-405.2 _|Slope...
- Panda S.51 All Aluminum Folding Door System
- Panda TS.60 Thermally Broken Folding Door System
- eone Bradley Classic Timepiece
- Mockett PCS79/WC Illuminated Wireless Charging Grommet
-
303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
Accessible Routes
Accessible route requirements in ADAAG address width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level, doors, egress, and areas...
-
Comments from Individuals Who Are Blind or Have Low Vision (Section-by-Section Analysis)
member of the advisory committee that recommended the proposed guidelines, but filed a minority report recommending detectable warning surfaces should be required only on curb ramps with slopes...
-
Suggested accessibility guidelines for exterior concrete surfaces
The deviation from slope or plane of formed surfaces over 10 feet (3 m) is ± 0.3% of length. This is approximately 3/8 inch in 10 feet (10 mm in 3 m)....
- Whitehall Mfg. WH2142T2 Ligature Resistant Toilet Top Supply On-Floor Wall Waste
- Salsbury Industries See Through Metal Locker Six Tier Box Style 1 Wide
- Salsbury Industries See Through Metal Locker Six Tier Box Style Bridge 16 Box