entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door, depending on direction...
Search Results "Up Direction"
Commonly Searched Documents
-
Question 10
-
A5. Accessible Parking Spaces
Are all accessible parking spaces, including the access aisle, relatively level (1:50 or 2%) in all directions?...
-
Running Slope (Grade)
The ascent or descent of a trail segment expressed as a percentage of its length, which is the difference in elevation of a section of a trail measured parallel to the predominant direction...
-
1018.6 Openings
Elongated openings should be placed so that the long dimension is perpendicular, or as close to perpendicular as possible, to the dominant direction of travel....
-
Can handrail extensions wrap or turn?
Otherwise, handrail extensions must be in same direction as the ramp run....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Egress Signage
Section 216.4 provides specific requirements for means of egress, including exit doors, areas of refuge, and directional signs....
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS MINIMUM MANEUVERING CLEARANCE Approach direction...
-
11B-404.3 Automatic and power-assisted doors and gates
using wheelchairs because holding the door open with one hand requires the user to let go of one wheel – not enough control remains to prevent the chair from twisting out of the intended direction...
-
11B-705.1.2.2.2.2 Two entrance/exit points
points, as measured perpendicular to the curb, and the turning space shall provide a minimum 36 inches (914 mm) wide portion without detectable warnings to allow pedestrian travel in the direction...
-
11B-1009.5.4 Transfer steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access....
-
What are the time limits for filing charges of discrimination?
there is a state or local fair employment practices agency that enforces a law prohibiting the same alleged discriminatory practice, it is possible that charges may be filed with EEOC up...
-
211.3 More Than Minimum Number
EXCEPTION: Where 50 percent of the drinking fountains yields a fraction, 50 percent shall be permitted to be rounded up or down provided that the total number of drinking fountains complying...
-
1009.5.4 Transfer Steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access....
-
Islands [4.7.11]
If there is no level space between ramps, wheelchairs can "bottom out" or "high center" while proceeding down one ramp while the back wheels are coming up the other slope....
-
Chapter 10: Recreation Facilities
The final rule adds technical requirements to Chapter 10 for outdoor constructed features (1011); parking spaces within camping units and picnic units and pull-up spaces at dump stations...
-
Controls [§404.3.5]
Recommendation: Placing controls in locations that preclude backing-up will facilitate usability....
-
Curb Ramps [§406]
Curb Ramps [§406] Requirements for curb ramps apply to ramps that cut through curbs or are built up to them....
-
Stairway Handrails Requirements in the ADA Standards (§504)
Protrusions up to 12” are specified for objects mounted on posts or pylons (§307)....
-
Can handrails or other elements overlap door maneuvering clearances?
However, door maneuvering clearances can be offset up to 8” from the face of the door or gate to accommodate wall thickness, casework, shelves, or other elements adjacent to doorways, including...
-
Can handrails overlap door maneuvering clearances?
However, door maneuvering clearances can be offset up to 8” from the face of the door or gate to accommodate wall thickness, casework, shelves, or other elements adjacent to doorways, including...
-
§1193.43(e) Availability of auditory information for people who are hard of hearing
For transmitted voice signals, provide a gain adjustable up to a minimum of 20 dB. For incremental volume control, provide at least one intermediate step of 12 dB of gain....
-
11B-228.1 General
Exception: Drive-up only depositories shall not be required to comply with Section 11B-309. [2010 ADAS] Advisory 228.1 General. ...