Q In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?...
Search Results "NFSI: National Floor Safety Institute"
Commonly Searched Documents
-
In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?
-
Wheelchair Transfer
The clear floor space requirements depend on how a person using a wheelchair can approach the toilet. Unlatching footrests allows a closer approach....
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that a person using a wheelchair or other mobility aid can enter and close the door, use the fixtures...
-
11B-604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
- Ohio Gratings Aluminum Swaged Bar Grating Video
- Ohio Gratings Informational Video
-
Safety Considerations
The ACAA does not require air carriers to disregard applicable FAA safety regulations....
-
4.2.8 Slope
The slope of the clear floor or ground space required by section 4.2.6 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
ADA Tolerances - Related Industry Standards
[See subsections ...]
-
ADA Tolerances Provisions
[See subsections ...]
-
Technical Memorandum TM 2013-17 Water Closet Clearance - Overlap
TM 2013-17 Water Closet Clearances - Overlap Effective Date: June 1, 2013 2012 TAS Reference: 604.3.2 Based on TAS 106.3 and the application of terms and definitions...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear...
-
4.8.6 Cross Slope and Surfaces
The cross slope of ramp surfaces shall be no greater than 1:50. Ramp surfaces shall comply with 4.5.
-
4.8.6 CROSS SLOPE AND SURFACES
The cross slope of ramp surfaces shall be no greater than 1:50. Ramp surfaces shall comply with 4.5.
-
Approach and Maneuvering Clearance [§305.6 and §305.7]
Approach and Maneuvering Clearance [§305.6 and §305.7] Where the space is obstructed on both sides for more than half the depth, additional clearance is required for maneuvering....
-
11B-604.3.1 Size
11B-604.3.1 Size. Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured...
-
§ 38.95(a)(2) Exception
(2) Exception. If level-entry boarding, portable or platform lifts, ramps or bridge plates meeting the applicable requirements of this section are provided on station platforms or...
-
§ 38.93(d)(3) Exception
(3) Exception. Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d)(1) or (d)(2) of this section, car, platform or portable lifts...
-
4.5.3 Slope
The slope of the clear floor or ground space for trash, recycling, and other essential containers shall not exceed 1:48 (2 percent) in any direction. Exception....
-
11B-604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
11B-604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
11B-1008.2.6 Ground surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. [2010 ADAS] Advisory 1008.2.6 Ground Surfaces. ...