Within play areas, protruding objects on circulation paths shall not be required to comply with Section 11B-307 provided that ground level accessible routes provide vertical clearance in...
Search Results "Hinge Side Clearance"
-
11B-204.1 General
-
M305.5 Head and Back Support (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients in the supine, prone, or side-lying position and the seated position that can be adjusted to a reclined position to...
-
M305.2.2 Length (Section-by-Section Analysis)
The Board restructured the Committee’s recommendations to fit within the end and side transfer supports discussed above....
-
Door stop
[See subsections ...]
-
Section 35.151(e) Social service center establishments
Section 35.151(e) Social service center establishments In the NPRM, the Department proposed a new Sec. 35.151(e) requiring group homes, halfway houses, shelters, or similar social...
-
M301.2.1, M302.2.1 Transfer Height
This is also coupled with the complication of a 6" tall lift clearance window that forces foot operated controls up....
-
Parking
access aisles. 11B-502.4 Identification at accessible spaces and/or lot entrances. 11B-502.6 11B-502.8 Vertical clearance...
-
Parking
access aisles. 11B-502.4 Identification at accessible spaces and/or lot entrances. 11B-502.6 11B-502.8 Vertical clearance...
-
11B-1002.4.4.2 Side entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
11B-1002.4.4.2 Side entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
11B-1002.4.4.2 Side entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
M305.2.1 Location (Section-by-Section Analysis)
For stretchers, the MDE Advisory Committee noted that patients enter from either of the long sides, rather than on one long side and one short side, and this change in orientation necessitated...
-
M305.2.6 Gripping Surface
Transfer support gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
7(2)(b)
(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor...
-
28.1 Q. If an architect or builder chooses to follow the bathroom specifications in Requirement 7...are the other bathrooms in the dwelling unit required to have reinforced walls for grab bars?
A. Yes. Requirement 6 of the Guidelines requires reinforced walls in bathrooms for later installation of grab bars. Even though Requirement 6 was not repeated under Requirement...
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side....
-
205 and 309 Operable Parts
205 and 309 Operable Parts Section 4.1.3, and more specifically sections 4.1.3(13), 4.27.3, and 4.27.4 of the 1991 Standards, require operable parts on accessible elements, along...
-
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment. The transfer or positioning support should be oriented horizontally on imaging equipment with transfer...
-
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces. Transfer supports for imaging equipment should be 28 inches minimum in length and...
-
i. Medical examination and treatment tables and chairs
i. Medical examination and treatment tables and chairs Healthcare providers use examination and treatment tables and chairs for many different types of medical and dental...
- Bradley Grab Bars 1 1/2" with Exposed Mounting 817
-
Position [§305.5]
Position [§305.5] At most elements, clear floor or ground space can be positioned for either a forward or a side approach....
-
11B-805 Medical care and long-term care facilities
A 36-inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....