[2010 ADAS] 608.2.2.1 Clearance....
Search Results "Hinge Side Clearance"
-
11B-608.2.2.1 Clearance
-
M301.3.3 Head and Back Support (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed to place the requirements for head and back support for diagnostic equipment used by patients in the supine, prone, or side-lying position in M301...
-
11B-232.2.1.1 Beds
In cells having more than 25 beds, at least 5 percent of the beds shall have clear floor space complying with Section 11B-807.2.3.
-
11B-232.2.1.1 Beds
In cells having more than 25 beds, at least 5 percent of the beds shall have clear floor space complying with Section 11B-807.2.3.
-
Beds: ADA Standard Section 232.2.1.1
Section 232.2.1.1 covers scoping requirements in the current ADA Standards for beds.
-
11B-1002.4.4 Clearances
Clearances for wheelchair spaces shall comply with Section 11B-1002.4.4. Exceptions: Where provided, securement devices shall be permitted to overlap required clearances....
-
11B-1002.4.4 Clearances
Clearances for wheelchair spaces shall comply with Section 11B-1002.4.4. Exceptions: Where provided, securement devices shall be permitted to overlap required clearances....
-
11B-608.2.2.1 Clearance
[2010 ADA Standards] 608.2.2.1 Clearance....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance. ...
- Midmark 623 Barrier-Free® Power Examination Table
- 309.3 Baby Changing Table Pull Down Handle Height
-
Bradley Grab Bars 1 1/4" with Concealed Mounting 832 142 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 142 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-403.5 Clearances
Walking surfaces shall provide clearances complying with Section 11B-403.5....
-
11B-403.5 Clearances
Walking surfaces shall provide clearances complying with Section 11B-403.5....
-
M301.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a supine, prone, or side-lying position must comply with the technical requirements of proposed section M301....
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface...
-
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment. Supports (transfer or positioning) should be located 1 ½ inches maximum from the transfer surface. The...
-
Homeless Shelters, Group Homes, and Similar Social Service Establishments
Homeless Shelters, Group Homes, and Similar Social Service Establishments. Section 233 of the 2010 Standards includes specific scoping and technical provisions that apply to new...
-
§ 38.23(c)(8) Handrails
(8) Handrails. If provided, handrails shall allow persons with disabilities to grasp them from outside the vehicle while starting to board, and to continue to use them throughout the...