Section 221.2 covers scoping requirements in the current ADA Standards for wheelchair spaces.
Search Results "Clear Ground Space"
-
Wheelchair Spaces: ADA Standard Section 221.2
-
1005.3.2 Extended Ground or Deck Surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum....
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum....
-
D2. Clear Passage
Does at least one door or one side of a double leaf door at the accessible entrance provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
11B-206.4.1 Entrances and exterior ground floor exits
All entrances and exterior ground-floor exits to buildings and facilities shall comply with Section 11B-404. [2010 ADAS] 206.4.1 Public Entrances. ...
-
11B-206.4.1 Entrances and exterior ground floor exits
All entrances and exterior ground-floor exits to buildings and facilities shall comply with Section 11B-404. [2010 ADAS] 206.4.1 Public Entrances. ...
-
11B-206.4.1 Entrances and exterior ground floor exits
All entrances and exterior ground-floor exits to buildings and facilities shall comply with Section 11B-404. [2010 ADA Standards] 206.4.1 Public Entrances....
-
R302.7 Surfaces
The surface requirements in R302.7 also apply to surfaces at the following accessible elements and spaces that connect to pedestrian access routes: • Clear spaces (see R404.2), including...
-
Elevated: ADA Standard Section 1008.2.4.2
The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1....
-
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]...
-
4.35.4 Bench
Clear floor space shall be provided alongside the bench to allow a person using a wheelchair to make a parallel transfer onto the bench....
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
Parking Spaces: ADA Standard Section 208
Section 208 covers scoping requirements in the most current ADA Standards for parking spaces.
-
1005.3.2 Extended Ground or Deck Surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....