The kitchen work surface shall be 34 inches (864 mm) maximum above the finish floor or ground....
Search Results "Teeing Ground"
-
11B-804.3.2 Height
-
11B.707.7.1.2 Angle-mounted display screen
the viewer 30 degrees to less than 60 degrees from vertical, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor or ground...
- SDC Bollard Post with Push Plate or Touch Panel
-
Entry Points and Seats: ADA Standard Section 1008.4.4
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
Dining Surfaces and Work Surfaces for Children's Use: ADA Standard Section 902.4
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
Use Zone
The ground level area beneath and immediately adjacent to a play structure or play equipment that is designated by ASTM F 1487 (incorporated by reference, see “Referenced Standards” in Chapter...
-
Forward Approach: ADA Standard Section 904.4.2
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Bench: ADA Standard Section 612.2
Section 612.2 covers the current ADA Standards for benches in saunas and steam rooms.
-
Question: Alteration vs. Maintenance for Stairs in Pre-ADA Building
The site in question is a large, pre-ADA building with retail on the ground floor and offices (not public accomodations) on the second floor....
- Indiana AgrAbility
-
Range or Cooktop: ADA Standard Section 804.6.4
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
1008 Play Areas
The play area specifications address accessible routes, ground level and elevated play components, play structures, and ground surfaces....
-
1014.2.1 Transfer Access
the camp shelter, and one full unobstructed side of the clear ground space to adjoin or overlap an outdoor recreation access route or trail, as applicable, or another clear ground space....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
Attachment J
Free-standing objects mounted on posts or pylons may overhang 12 inches maximum from 27 inches to 80 inches above the ground or finished floor. Standards § 4.4....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....