Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
Search Results "Sloped Sidewalk"
Commonly Searched Documents
-
§ 38.95(c)(3) Ramp threshold
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1134A.6 Showers
Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
Roundabouts (Section-by-Section Analysis)
Where sidewalks are flush against the curb at roundabouts and pedestrian street crossing is not intended, a continuous and detectable edge treatment must be provided along the street side...
-
Q4: Road Alteration Projects that Trigger Curb Ramp Improvements Not on State/Local Property
Q4: When a road alteration project triggers the requirement to install curb ramps, what steps should public (State or local) entities take if they do not own the sidewalk right-of-way needed...
-
Issue 9: Reach (how far?)
Figure 12 shows a location where new APS (and new sidewalks) were installed, but the APS are not usable....
-
Small governmental jurisdictions affected by proposed accessibility guidelines
., sidewalks, pedestrian street crossings, and pedestrian signals)....
-
General (R304.1) (Section-by-Section Analysis)
Blended transitions are raised pedestrian street crossings, depressed corners, or similar connections between the pedestrian access route at the level of the sidewalk and the level of the...
-
THE SETTLEMENT CLASS
to the City) with any mobility disability, who, at any time from the beginning of time through the thirty-year term of the Settlement Agreement: (1) accessed or attempted to access any sidewalks...
-
E. Chapter 4: Boarding and Alighting
Responses to comments on the Board’s proposal in the 2010 NPRM to revise the technical requirements for the slope of ramps in non-rail vehicles by specifying a single standard (1:6) for...
-
Dispersion
Clustering wheelchair spaces is allowed only where sight line slopes exceed 5%, such as bleachers and balconies (or in alterations where dispersion is technically infeasible)....
-
M303.3.2 Beveled (Section-by-Section Analysis)
proposed that for equipment with a change in level at the entry to the wheelchair space, level changes greater than ¼ inch but not greater than ½ inch would be required to be beveled with a slope...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
4(6)
The finished surface of this area that is located immediately outside the entry may be sloped, up to 1/8 inch per foot (12 inches), for drainage. ...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
f-v
[ADA Standards § 4.8.4] Yes No Note: if the running slope is less than 1:16 but more than 1:20, each ramp segment may be up to 40 feet long followed by a level landing]....
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
4d.
[ADA Stds 4.8.4] Yes _____ No _____ Note: When the running slope is less than 1:16 and more than 1:20, each ramp segment may be up to 40 feet long followed by a level landing....
-
6d. Ramp Length
[ADA Stds 4.8.4] Note: When the running slope is less than 1:16 and more than 1:20, each ramp segment may be up to 40 feet long followed by a level landing. Yes _____ No _____...
-
Gripping Surface: ADA Standard Section 505.6
Section 505.6 covers the current ADA Standards for the handrail gripping surface.
-
11B-505.6 Gripping surface
Exceptions: Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along...
-
Transfer Access [1014.2.1]
When the surface of the clear ground space is constructed of asphalt, concrete, or boards, the slope of the clear ground space must be no steeper than 1:48 (2 percent) in any direction....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...