Post shall be 1/2" x 1" (13 X 25) rectangular tubing with formed mounting flange and bracket welded on end....
Search Results "End of Row Compartment"
Commonly Searched Documents
- American Specialties Single Robe Hook 7340
- Landscape Forms Inc. Parc Vue Bench Collection
-
Clear floor space beside or between beds must be 36" wide
Remember that because the clear floor space required by 806.2.3 will be deeper than 24" to end up beside or between the beds where it will be usable, it will be in an alcove that is at least...
- Landscape Forms Inc. Strata Bench Collection
-
Scope: ADA Standard Section 201.1
Section 201 discusses the scope of the ADA Standards.
-
Section H: Lifts
(ยงยง410.5, 309.4) ย ย ย ย H6 Is the clear width of the door opening/gate opening at the end of the lift at least 32"?...
-
610.3.2 L-Shaped Seats
The end of the "L" shall be 22 inches (560 mm) minimum and 23 inches maximum (585 mm) from the main seat wall....
-
606.4 Faucets and Water Spray Units
For the reasons stated in the preamble, we amend 36 CFR part 1191 as follows: In 606.4, revising the heading to read โFaucets and water spray units,โ and adding a sentence at the end...
-
Filenames and paths in place of alt-text
This is useful for developers who need to find where they got the file from, but it is useless for end-users of the document who use screen readers....
-
11B-216.1 General
Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos shall not be required to comply with Section 11B...
-
TICKETINGย
identified; Tickets for accessible seating must be available at all price levels; A wheelchair user may purchase up to three companion seats that are contiguous and in the same row...
-
11B-216.1 General
Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos shall not be required to comply with Section 11B...
- Landscape Forms Inc. FGP Bench Collection
- Kawneer North America 2000T Terrace Doors
- The Smith-Kettlewell Eye Research Institute
-
DSA IR 11B-2: BEVELED LIP AT CURB RAMPS (with revisions issued through Jan. 2011)
CBC Section 1127B.5 Item 5 states: "The lower end of each curb ramp shall have a 1/2 inch (13 mm) lip beveled at 45 degrees as a detectable way-finding edge for persons with visual impairment...
-
ยง382.7(b)
(b) If you are a foreign carrier, this part applies to you only with respect to flights you operate that begin or end at a U.S. airport and to aircraft used for these flights....
-
Addendum A: List of Terms
If the participant does not end on the desired platform it is considered a failed transfer....
-
4.3.5.2 180-degree turn
These data are based on measurements of wheeled mobility users performing 180-degree turns in a dead-end hallway, built with mock walls....
-
28 CFR Part 36, Appendix C: Guidance on ADA Regulation on Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities (2010 ADA Title III Regulations: 1991 Preamble and Section-by-Section Analysis)
nondiscrimination on the basis of disability by public accommodations and in commercial facilities beginning at the heading "Section-by-Section Analysis and Response to Comments'' and ending...
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the wheelchair...
-
M305.3.2 Height (Section-by-Section Analysis)
For vertical supports, the MDE NPRM proposed that the bottom end of the support be 34 inches high minimum and 37 inches high maximum above the standing surface....
-
M304.2.2 Standing Supports (Section-by-Section Analysis)
In addition, the Access Board has added a new exception for diagnostic equipment with entry and exit that permits pass-through from one end to another to provide one standing support provided...