11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
Flush Controls on Toilets
2010 ADA Standards Flush Controls for accessible toilets are require to be on the open side of the water closet Flush Controls for accessible water closets and toilet compartments...
-
T502.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (810 mm) minimum.
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
603.2.3 Door Swing
603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space....
-
Scoping [4.1.3(7)]
Scoping [4.1.3(7)] Doors required to be accessible include: at least one door at each accessible entrance at least one door at each accessible space within a building...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
- SafeZone: Norton SafeZone Overview
- Remote Control Curtain.Com CL 920 Unfolding and Reassembling Motorized Curtain Track Instructional Video
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System Pocket Door Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
Doorways
In transient lodging facilities, doors and doorways in inaccessible guest rooms are required to be at least 32 inches wide (224.1.2)....
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL...