Search Results "Court Floor Holding Cell"
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
L. Lavatory
wash basin) in each public restroom that has each of the following characteristics... ...a 29" high clearance under the front edge and the top of the bowl no higher than 34" above the floor...
-
303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2....
-
303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1....
-
303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2....
-
11B-303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with Section 11B-303....
-
§ 38.93(d)(4) Exception
Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
11B-303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with Section 11B-303. Exceptions: 1.     ...
-
11B-303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with Section 11B-303. Exceptions: 1.    ...
-
Forward Approach
Forward Approach Clear floor space is required to the face of the unit; a portion can be provided below the unit where clearance is available for toes/knees....
-
4.4.5 Slope
The slope of the clear floor or ground space for benches shall not exceed 1:48 (2 percent) in any direction. Exception....
-
11B-604.3.1 Size
ETA Editor's Note The CBC 11B-604.3.1 requirement for maneuvering space in front of accessible water closets exceeds the 2010 ADA Standards requirement for water closet clear floor...
- Access Board: Tactile Sign Clear Floor Space
-
3.4.4 Clear Ground Space and Turning Space
Each viewing area that is required to be accessible by section 3.4.1 shall have a clear ground or floor space 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum positioned for either...
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...