Do not use short shower benches. Do not use backless shower benches. Definitely avoid curved seats like this example to the left....
Search Results "Bench Height"
-
Bathroom Do’s and Dont’s
-
Vertical Clearance [§307.4]
Fixed planters, benches, and other elements can be used instead of guardrails....
-
5 “G’s” Getting Access to Health Care for People with Physical Disabilities
By June Isaacson Kailes, Associate Director Center for Disability Issues and the Health Professions Western University of Health Sciences jik@pacbell.net 2008...
-
11B-803.6 Mirrors
shall be full length with a reflective surface 18 inches (457 mm) wide minimum by 54 inches (1372 mm) high minimum and shall be mounted in a position affording a view to a person on the bench...
-
11B-803.6 Mirrors
shall be full length with a reflective surface 18 inches (457 mm) wide minimum by 54 inches (1372 mm) high minimum and shall be mounted in a position affording a view to a person on the bench...
- Acess-Able Designs Portable Tub/Shower Transfer Bench SH-425
- Access-Able Designs Wall Mounted Shower Transfer Bench SH-400
-
11B-226.1 General
With respect to work surfaces, this means that employers may need to procure or adjust work stations such as desks, laboratory and work benches, fume hoods, reception counters, teller windows...
- Pressalit Care PLUS Support Arm Fixed Height Swing Grab Bar
- Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar
- EZ Dock EZ Launch® System for Kayaks and Canoes
-
6.1 Deliberative Process
At its first meeting, the Advisory Committee considered this NPRM recommendation of 17” to 19”, which applied to either fixed or adjustable height transfer surfaces....
-
Water Closet Centerline and Seat Height
Water closets are to be located so that the centerline is 16 to 18 inches from the side wall compartment partition (604.2). Water closets can be located so that this dimension is met...
-
4.2.4 Height of Fire-Building Surface
The fire-building surface within a fire ring shall be at least 9 inches (230 mm) above the floor or ground.
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1136A.2 Switch and control heights
Controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating...
-
1136A.2 Switch and control heights
Controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
R212 Street Furniture (Section-by-Section Analysis)
At least 50 percent, but no less than one, of benches at each location must provide a clear space for a wheelchair adjacent to the bench. Benches at tables are not required to comply....
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
Because the picture was taken directly from the ANSI A117.1 1986 standard, the diagram also shows the height of the obstruction, which, in this picture, is a countertop....
-
Raised Courtroom Stations Not for Members of the Public
One commenter suggested that a sufficient number of accessible benches for judges with disabilities, in addition to requiring accessible witness stands and attorney areas, be required....
-
Hotel Bed Height
Thanks, Kaylan. This is very helpful. I did not know you responded to my question until today. I wish Corada would send an email to alert you that someone responded to your...
-
Scoping Requirements
For instance, if a bench is provided at a viewing area, the scoping requirements apply to the bench....
- Boost Your Business - Chapter 10 - Restroom Fixtures