Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
Search Results "Shall"
-
11B-608.2.2 Standard roll-in type shower compartments
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
101.4.3 Plumbing
The provisions of the California Plumbing Code shall apply to the installation, alteration, repair and replacement of plumbing systems, including equipment, appliances, fixtures, fittings...
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.2.2
Section 608.2.2 covers the current ADA Standards for the size of standard roll-in type shower compartments.
-
Height: ADA Standard Section 407.2.1.1
Section 407.2.1.1 covers the current ADA Standards for the height of the elevator call controls.
-
Minimum Number: New Construction: ADA Standard Section 233.3.1
Newly constructed facilities with residential dwelling units shall comply with 233.3.1....
-
11B-407.4.6 Elevator car controls
Where provided, elevator car controls shall comply with Sections 11B-407.4.6 and 11B-309.4....
-
11B-246.2 Camping facilities
In camping facilities where campsites are provided, at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected to sanitary...
-
11B-502.6.3 Location
A parking space identification sign shall be visible from each parking space....
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall comply with Sections 1009.3.1 through 1009.3.3....
-
11B-246.2 Camping facilities
In camping facilities where campsites are provided, at least two campsites and one additional campsite for each 100 campsites or fraction thereof, shall be accessed by and connected to sanitary...
-
11B-809.8.1 Door Thresholds
Primary entry doors, required exit doors, and interior doors intended for user passage shall have thresholds complying with Section 11B-404.2.5....
-
11B-407.4.6 Elevator car controls
Where provided, elevator car controls shall comply with Sections 11B-407.4.6 and 11B-309.4....
-
11B-241.1 General
Where provided, saunas and steam rooms shall comply with Section 11B-612....
-
11B-502.6.3 Location
A parking space identification sign shall be visible from each parking space....
-
11B-241.1 General
Where provided, saunas and steam rooms shall comply with Section 11B-612....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall comply with Sections 1009.3.1 through 1009.3.3....
-
3104.2 Separate structures
Buildings connected by pedestrian walkways or tunnels shall be considered to be separate structures....
-
11B-232.1 General
Cells with mobility features shall be provided in each classification level. 2) Alterations to detention and correctional facilities. ...
-
11B-232.1 General
Cells with mobility features shall be provided in each classification level. 2) Alterations to detention and correctional facilities. ...
-
11B-213.2 Toilet rooms and bathing rooms
Where toilet rooms are provided, each toilet room shall comply with Section 11B-603. Where bathing rooms are provided, each bathing room shall comply with Section 11B-603....
-
1010.1.4 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....