Findings prepared by fire protection districts shall be ratified by the local city, county, or city and county and filed with the California Department of Housing and Community Development...
Search Results "Edge Protection"
Commonly Searched Documents
-
1.1.8.1 Findings and filings
-
9.2.2(6)
EXCEPTION: The requirements of 4.13.8 and 4.3.8 do not apply where it is necessary to utilize a higher door threshold or a change in level to protect the integrity of the unit from wind/...
-
Motor Impairments
Employers may want to provide heavy gloves to protect individuals' hands from debris when pushing their manual wheelchairs, a patch kit to repair flat tires, and extra batteries for those...
-
§ 38.23(d)(4) Orientation
Such barriers need not be solid provided equivalent protection is afforded....
-
1009.4 Elevators
Areas of refuge are not required at elevators serving smoke-protected assembly seating areas complying with Section 1029.6.2....
- Georgia Council on Developmental Disabilities (GCDD)
- Willoughby Industries 2260 AquaDeck Lavatory Deck Contoured Front
- Federal Service Dog Law in Plain English
-
Section 36.103 Relationship to Other Laws (Section-By-Section Analysis and Response to Comments)
Congress did not intend to displace any of the rights or remedies provided by other Federal laws or other State or local laws (including State common law) that provide greater or equal protection...
-
Klingstone 400
The segment contains timber edging. The Klingstone 400 is applied to materials on top of a base, which is composed of 4 inches of ¾ inch minus limestone and dust....
-
5.3.2 Transfer Sides Recommendations for M301
The provisions result in the transfer surface being located at a corner of the equipment and the two transfer sides adjoining at the edges of the equipment (e.g., foot of an examination...
-
5.7.1 Lift Compatibility Clearance in Base for M301
The base of the equipment shall provide a clearance 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge of the examination...
-
Notes:
Measured from the point on the floor where a perpendicular line intersects the front edge of breast platform shown in Figure 10....
-
Handrails [4.8.5]
The height of a guardrail (to prevent falling off the edge) is not specified by ADAAG; local building codes do, however, commonly regulate the minimum height of a guardrail at 42 inches....
-
Construction Specification Institute
longitudinal lines, measurements were to be taken in minimum 5 - foot lengths running parallel to the long dimension, with one measurement line per 3 feet of width and within 2 feet of edges...
-
Handrails Along Walking Surfaces [§403.6, §505]
Handrails can have circular or non-circular cross-sections, but must have rounded edges. The gripping surface and adjacent surfaces must be free of abrasive or sharp elements....
-
§ 38.23(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
§ 38.95(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle symbol shall be located 1/4 inch (6.4 mm) maximum from the edge of the circle symbol with a vertex pointing upward....
-
§ 38.125(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
1015.2 Where required
aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge...
-
§ 38.83(b)(13) Handrails
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...