Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm)...
Search Results "Covered Multifamily Dwelling Unit (CBC 11A)"
-
11B-809.10.4 Sufficient maneuvering space
-
Maneuvering Space, Adjustable Cabinetry, Fixtures and Plumbing
Comment. A number of commenters from the disability community stated that it was important that the Guidelines for both kitchens and bathrooms specify a five-foot turning radius;...
-
233.3.1.2.2.2 Units Installed, F233.4.1.2.2.2 Units Installed
Amendatory Language For the reasons stated in the preamble, we amend 36 CFR part 1191 as follows: Adding new sections 233.3.1.2.2.2 to read as follows: 233.3.1.2.2.2 Units Installed...
-
Shower Spray Unit
The guidelines require tubs to have shower spray units that can be used as both a fixed position shower head and a hand-held shower (607.6)....
-
Picnic Unit
An outdoor space within a picnic area or facility that is designed and constructed for picnicking and that contains one or more constructed features such as picnic tables, grills,...
-
11B-607.6 Shower spray unit and water
The shower spray unit shall have an on/off control with a non-positive shut-off....
-
11B-607.6 Shower spray unit and water
The shower spray unit shall have an on/off control with a non-positive shut-off....
-
F244.2.3 Elements within Camping Units with Mobility Features
This section contains the scoping requirements for elements within camping units required to provide mobility features, including outdoor constructed features (F244.2.3.1), parking spaces...
-
Guidelines for Requirement 2
For individual dwelling units, the Act limits its requirements to specific features of accessible design. Comment....
-
11B-233.3.1.2.6.5 Additional requirements.
In buildings without elevators and where site impracticality test numbers one, two or three reduce the required number of residential dwelling units with adaptable features, the remaining...
-
Picnic Units
Each picnic unit may be used separately from other parties using the recreation site....
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel bars are provided, no less than...
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
233.3.1.2 Facilities Containing Emergency Transportable Housing Units, F233.3.1.2 Facilities Containing Emergency Transportable Housing Units, F233.4.1.2 Facilities Containing Emergency Transportable Housing Units
233.3.1.2 Facilities Containing Emergency Transportable Housing Units F233.3.1.2 Facilities Containing Emergency Transportable Housing Units F233.4.1.2 Facilities Containing Emergency...
-
233.3.1.2 Facilities Containing Emergency Transportable Housing Units, F233.4.1.2 Facilities Containing Emergency Transportable Housing Units
233.3.1.2 Facilities Containing Emergency Transportable Housing Units F233.4.1.2 Facilities Containing Emergency Transportable Housing Units These sections contain the scoping requirements...
-
Basic Components for Accessible and Usable Public and Common Use Areas or Facilities
[See subsections ...]
-
4.21.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
4.21.6 SHOWER UNIT
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...