3. A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm).
Search Results "Covered Multifamily Dwelling Unit (CBC 11A)"
-
1133A.7, Item 3
-
1132A.3, Item 4
4. A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable.
-
1133A.7, Item 3
3. A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm).
-
11B-809.9.7 Exposed pipes and surfaces
Exposed water supply and drain pipes under sinks and lavatories shall comply with Section 11B-606.5.
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum.
-
11B-809.10.8.3 Cabinets
Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory.
-
11B-809.9.2 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, work surface or the face of any appliance (excluding handles and controls) and the opposing cabinet, work...
-
Controls: ADA Standard Section 608.5
Section 608.5 covers the current ADA Standards for controls in shower compartments.
-
7(1)(c)
(c) In U-shaped kitchens with sink or range or cooktop at the base of the "U", a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that...
-
CASI Accessibility Construction Inspection Checklist
This checklist is based on the 2013 California Building Code (CBC), Part 2, Title 24, California Code of Regulations and should be used in conjunction with the regulations found in Chapter...
-
CALBO Accessibility Construction Inspection Checklist
This checklist is based on the 2013 California Building Code (CBC), Part 2, Title 24, California Code of Regulations and should be used in conjunction with the regulations found in Chapter...
-
11B-217.4.3.2 Private buildings
Exception: In a stadium or arena, in a convention center, in a hotel with a convention center or in a covered mall, if an interior public pay telephone is provided at least one interior...
-
3.2.2 ORARs in Camping Units
Connections shall be provided between site furnishings and constructed features in camping units as well as between accessible camping units, parking areas, and accessible common use features...
-
11B-604.5 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
-
Camping Units With Mobility Features [F244.2]
When different types of camping units are provided (e.g., camping units for RVs only or tent camping only, or camping units with camp shelters), table 5 applies to each type of camping unit...
-
F244.2 Camping Units with Mobility Features
Table F244.2 Camping Units with Mobility Features Total Number of Camping Units Provided in Camping Facility Minimum Number of Camping Units with Mobility...
-
11B-604.5 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
-
11B-604.5 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
-
3.2.6 Identification of Accessible Camping Units
They shall not be identified using individual signs adjacent to the camp units. Exception 1....
-
PUBLIC HOUSING
While the text of Chapter 11A, Section 1101A.1 partially reads “Newly constructed covered multifamily dwellings, which can also be defined as public housing, shall be subject to the requirements...
-
233.3.1.2.2.2 Units Installed, F233.4.1.2.2.2 Units Installed
Amendatory Language For the reasons stated in the preamble, we amend 36 CFR part 1191 as follows: Adding new sections 233.3.1.2.2.2 to read as follows: 233.3.1.2.2.2 Units Installed...
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the...
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm)...
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the bathrooms or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...