The shower spray unit shall have an on/off control with a non-positive shut-off....
Search Results "Control End Wall"
-
607.6 Shower Spray Unit and Water
-
607.6 Shower Spray Unit and Water
The shower spray unit shall have an on/off control with a non-positive shut-off....
-
Vibrotactile WALK indications
Vibrotactile WALK indications Vibrotactile indications are transmitted by a vibrating plate or arrow on the housing of the pedestrian pushbutton. During WALK, the arrow or plate...
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
Issue 14: Inspection of contractor’s work - Beware of field changes! Figure 18: APS and curb ramps that were not installed as designed. Figure 19: Another view of the...
-
F229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. In accessible rooms or spaces, each glazed...
-
229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed opening required by an...
-
Toilet Rooms North (Celebrity Spies)–Women [sic]
Toilet Rooms North (Celebrity Spies)–Women [sic]: ff. The force required to push or pull open the women's toilet room door is 10 lbf, which exceeds the maximum allowable door...
-
§27.71(k)(4) Privacy.
(4) Privacy. Automated airport kiosks must provide the opportunity for the same degree of privacy of input and output available to all individuals. However, if an option is provided...
-
§ 27.71(k)(4) Privacy
(4) Privacy. Automated airport kiosks must provide the opportunity for the same degree of privacy of input and output available to all individuals. However, if an option is provided...
-
229.1 General
229.1 General. Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed opening required...
-
11B-229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11B-309 _|Operable Parts|_. Each glazed...
-
11B-229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11B-309. Each glazed opening required by...
-
11B-607.6 Shower spray unit and water
The shower spray unit shall have an on/off control with a non-positive shut-off....
-
Keypads: ADA Standard Section 407.4.6.3
Section 407.4.6.3 covers the current ADA Standards for elevator car control keypads.
-
11B-404.1 General
A sign visible from the approach side complying with Section 11B-703.5 shall be posted stating “Entry restricted and controlled by security personnel”....
-
11B-404.1 General
A sign visible from the approach side complying with Section 11B-703.5 shall be posted stating “Entry restricted and controlled by security personnel”....
-
End of Checklist
END OF CHECKLIST...
-
§27.71(k)(3)(iii) Status Indicators.
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
-
§ 27.71(k)(3)(iii) Status indicators
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
- Viking Talk-A-Phones ETP-400V and ETP-400DV, Panel Phone E-1600A-TP-EWP
-
Significant alternatives which minimize any significant economic impacts on small entities
Maximum cross slope of 2 percent required on pedestrian access routes, including within pedestrian street crossings with yield or stop control....
-
Exceptions for Specific Occupancies [§206.2.3]
Exceptions for Specific Occupancies [§206.2.3] The Standards also include limited exceptions for accessible routes between stories in air traffic control towers and, under certain...
-
Guidelines for Environmental Infection Control in Health-Care Facilities (excerpts related to service animals only)
Guidelines for Environmental Infection Control in Health-Care Facilities Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC) U.S....
-
Section I: Elevators
(§§407.2.1.1, 308.2, 308.3) I4 Are elevator car controls 48" high or lower?...