., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than 1/2 inch (12.7 mm) of change in height between floor surfaces....
Search Results "Closer Height"
Commonly Searched Documents
-
11B-809.8 Doors
-
Issue 4: Wrong pole! …Wrong message!
Since the APS is closer to the departure curb and curb ramp for crossing straight ahead (in line with the photographer’s direction of travel), a pedestrian hearing the sound from that APS...
-
Stroke Thickness: ADA Standard Section 703.5.7
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following:
-
4.3.9 Doorway Design
Closers are not necessarily bad for accessibility. In fact, they reduce the difficulty of the most difficult maneuvering tasks, i.e. closing maneuver and closing tasks....
-
Pictogram Field: ADA Standard Section 703.6.1
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
11B-705.1.1.1 Dome size
warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and 0.47 inch (11.9 mm) maximum, and a height...
-
Parking sign height measurement technique
502.6 says "Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign." But which floor or ground surface? The...
-
Swimming Pools, Wading Pools & Spas
Word Fillable Form (2.8MB) Word Non-Fillable Form (2.6MB) PDF Non-Fillable Form (1.0MB)
-
11B-411.2.1.2.3 Accessibility function button
The International Symbol of Accessibility shall comply with Section 11B-703.7.2.1, and shall be 5/8 inch (15.9 mm) minimum in height. The indication shall be three raised dots....
-
Character Proportions: ADA Standard Section 703.2.4
Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
Character Proportions: ADA Standard Section 703.5.4
Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
Shower/Tub Seat Mounting Location
If the seat is in the down position, it does put the user closer to the shower and water controls while using the shower, but if someone is standing in the shower the seat obstructs the...
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent vehicular...
-
Front grab bar protocol
Adjustable height protocol). ...
-
Clearances for Side Approaches
Clearances for Side Approaches Clearance for side approaches are based on the swing of doors, direction of approach (hinge or latch), and the provision of closers (in some cases latches...
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
11B-225.2.3 Library book stacks
ETA Editor's Note The ADA Advisory identifies library shelving as self-service shelving, which does not have a height limitation....
- Hoyer Advance-E Power Lift
- 604.7 Open Type Toilet Paper Dispenser Height
- 902.3 Baby Changing Table Work Surface Height