If the drinking fountain is a wall-mounted unit, is there clear floor space at least 30 inches wide (36 inches if it is in an alcove) x 48 inches long in front of the drinking fountain and...
Search Results "Clear Width"
Commonly Searched Documents
-
J1
-
B. Question 2: Section 904.4.1 and Clear Counter Space
An entity does not violate the length requirement, where applicable, when it “maintain[s] merchandise or other items on the counter top, thereby failing to maintain 36-inches of clear counter...
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
- Magnuson Group RIGA Series Waste Receptacle
-
Accessible Parking Spaces [§502]
Accessible Parking Spaces [§502] Requirements for accessible parking spaces address the size and marking of regular and van spaces and access aisles, surfaces, vertical clearance...
-
904.4.1 Parallel Approach
A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter....
-
Figure M4: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and M304 Diagnostic Equipment for Use by a Patient in a Standing Position (Weight Scale Example)
Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. The weight scale is usable by both people who are...
-
§ 38.125(b)(6) Platform surface
The lift platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the lift platform surface to 30 inches...
- Boost Your Business - Chapter 9 - Restroom Clear Space
-
904.4.1 Parallel Approach
A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter....
-
904.4.1 Parallel Approach
A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter....
-
Attachment E
The toilet room that is currently designated for people with disabilities is not accessible because the door swings into the single user toilet room and encroaches upon the required clear...
-
Controls [§404.3.5]
Clear floor space at controls must be located outside the door swing to prevent users from getting hit by the door....
-
604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
-
Lavatories Adjacent to Partitions
Per 11B-606.2, we know that a clear space positioned for a forward approach is required (with exceptions), with proper knee and toe clearance. ...
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....