One full, unobstructed side of the clear ground space must adjoin or overlap an ORAR or trail, as applicable, or another clear ground space....
Search Results "Clear Tread Width"
-
Distinct Viewing Locations [F246.2, 1015.2, and 1015.3]
-
4.31.2 CLEAR FLOOR OR GROUND SPACE
A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
-
1133A.2, Item 4
The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space, appliance...
-
707.2 Clear Floor or Ground Space
707.2 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided....
-
Range or Cooktop: ADA Standard Section 804.6.4
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
1017.8.2 Width
Where resting intervals are provided within the trail tread, resting intervals shall be at least as wide as the widest segment of the trail tread leading to the resting interval. ...
-
1017.8.2 Width
Where resting intervals are provided within the trail tread, resting intervals shall be at least as wide as the widest segment of the trail tread leading to the resting interval....
-
Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)
[See subsections ...]
-
4.2.8 Slope
The slope of the clear floor or ground space required by section 4.2.6 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
4.5.3 Slope
The slope of the clear floor or ground space for trash, recycling, and other essential containers shall not exceed 1:48 (2 percent) in any direction. Exception....
-
3.4.5 Grade
The clear ground space and turning space required by section 3.4.3 shall have a slope of no more than 1:48 (2 percent) in any direction. Exception....
-
707.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
707.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
11B-805.4.2 Equipment
Clear space complying with Section 11B-305.2 shall be provided as required for specific equipment....
-
11B-805.4.2 Equipment
Clear space complying with Section 11B-305.2 shall be provided as required for specific equipment....
-
R404.6 Approach
One full unobstructed side of a clear space shall adjoin a pedestrian access route or adjoin another clear space....
-
11B-1008.2.6 Ground surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. [2010 ADAS] Advisory 1008.2.6 Ground Surfaces. ...
-
11B-1008.2.6 Ground surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. [2010 ADAS] Advisory 1008.2.6 Ground Surfaces....
-
11B-1008.2.6 Ground surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. Advisory 11B-1008.2.6 Ground surfaces....
- Figure 810.3 Bus Shelters – Drawing from the U.S. Access Board
-
1015.3 Viewing Space
Each distinct viewing location shall provide a viewing space adjacent to the clear ground space required by 1015.2 through which the point of interest is viewable....