Location of indicators shall comply with Section 11B-407.4.8.1.2.
Search Results "Car Ramp"
-
11B-411.4.8.1.2 Location
-
11B-411.4.8.1.1 Size
Characters shall comply with Section 11B-407.4.8.1.1.
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum....
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum....
-
f-iv
Does the ramp have a level landing at the top and bottom of each ramp section that is at least 60 inches long?...
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
11B-406.5.5 Wet conditions
Curb ramps and blended transitions shall comply with Section 11B-405.10....
-
T402.8 Running Slope
The maximum running slope of ramps and bridgeplates shall comply with T402.8.1 or T402.8.2....
-
11B-406.5.5 Wet conditions
Curb ramps and blended transitions shall comply with Section 11B-405.10....
-
11B-406.5.5 Wet conditions
Curb ramps and blended transitions shall comply with Section 11B-405.10....
-
T402.6 Clear Width
The clear width of ramps and bridgeplates shall be 30 inches (760 mm) minimum....
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
Q5.) What dimensions and conditions can practitioners reasonably consider to be compliant when the conditions, as constructed, do not meet the technical requirements exactly and there are no official, published, industry-developed tolerances?
capabilities of the materials and processes, David Ballast generally recommends a tolerance of 0.5% in the cross slope direction and 1.0% in the direction of travel for concrete or asphalt ramps...
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
Additional Number and Types: ADA Standard Section 240.2.1.2
Section 240.2.1.2 covers scoping requirements in the current ADA Standards for additional number and types of ground level play components.
-
11B-240.2.1.2 Additional number and types
Exception: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play...
-
11B-240.2.1.2 Additional number and types
Exception: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play...
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
Rough Form and Foundation Inspection
areas, and other site arrival points) to ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps...
-
Rough Form and Foundation Inspection
areas, and other site arrival points) to ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps...
-
d-iv
Are the handrails mounted 34 to 38 inches above the ramp surface? [ADA Standards § 4.8.5] Yes No...