Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2, 11B-703.3 and 11B-703.4.
Search Results "Toilet Room Signage"
-
11B-703.6.3 Text descriptors
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-703.7.2.2 International Symbol of TTY
The International Symbol of TTY shall comply with Figure 11B-703.7.2.2.
-
11B-810.6.3 Station names
Stations covered by this section shall have identification signs complying with Section 11B-703.5. Signs shall be clearly visible and within the sight lines of standing and sitting...
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. Heights of low resolution...
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3. Raised characters shall be installed in accordance with...
-
11B-703.6.3 Text descriptors
Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with Sections 11B-703.2, 11B-703.3 and 11B-703.4.
-
11B-703.7.2.3 Volume control telephones
Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3.
-
11B-703.2.2 Case
Characters shall be uppercase.
-
4.35.2 Clear Floor Space
A clear floor space allowing a person using a wheelchair to make a 180-degree turn shall be provided in every accessible dressing room entered through a swinging or sliding door....
-
806.3 Guest Rooms with Communication Features
Guest rooms required to provide communication features shall comply with 806.3. Advisory 806.3 Guest Rooms with Communication Features....
-
806.3 Guest Rooms with Communication Features
Guest rooms required to provide communication features shall comply with 806.3. Advisory 806.3 Guest Rooms with Communication Features....
-
223 Medical Care and Long-Term Care Facilities
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient or resident sleeping rooms shall be provided in accordance...
-
224 Transient Lodging Guest Rooms
224 Transient Lodging Guest Rooms...
-
Can doors swing into required clear floor or ground space?
clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5) fixture clearances in toilet...
-
F216.9.1 Identification Signs
Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
216.9.1 Identification Signs
216.9.1 Identification Signs. Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
At least fifty percent of the entrances must be accessible.
• At least fifty percent of the entrances must be accessible. Those that are not accessible must have signs that direct the public to the nearest accessible entrance.
-
Accessible Entrances
Accessible Entrances One small step at an entrance can make it impossible for individuals using wheelchairs, walkers, canes, or other mobility devices to enter a public facility....
-
1008.1.9.7, Item 5
5. A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: “KEEP PUSHING. THIS DOOR WILL OPEN IN 15 [30] SECONDS ALARM...
-
216.9.1 Identification Signs
Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2.
-
§ 38.27 Priority seating signs
[See subsections ...]
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.