Though the strobe requires external power to operate, rest assured that communication is possible, even during power failures!...
Search Results "Operating System"
Commonly Searched Documents
- Viking E-1600A-BLT-EWP Emergency Tower Phone with Blue LED Beacon and Strobe Light
- inLOOP Personal Loop Digital 600
-
2.1.3 Receivers
2.1.3 Receivers The major advantage of IL systems is that they permit listeners whose hearing aids incorporate telecoils to use their own hearing aids as the receiver....
-
§ 38.123(a)(5)
Door latches and hardware shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist....
-
11B-219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
11B-219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
11B-219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Visible alarms shall be activated by the in-room smoke alarm and the building fire alarm system....
- Viking E-1600A-BLT2EWP Emergency Tower Phone with Blue Strobe Light, Voice Announcer and Weather Protection
- Norton Surface Mounted 7100SZ Series SafeZone® Electromechanical Closer
-
§ 38.127(c)
(c) Controls and operating mechanisms (e.g., heating and air conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48 inches, and...
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215. [2010 ADA Standards] 215.1 General....
-
[F] 907.5.2.3.3 Groups R-1 and R-2.1
sleeping units in accordance with Table 907.5.2.3.3 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke alarm and the building fire alarm system...
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
sleeping units in accordance with Table 907.5.2.3.2 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke alarm and the building fire alarm system...
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215....
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215.  ...
-
1009.8 Two-way communication
Exceptions: Two-way communication systems are not required at the landing serving each elevator or bank of elevators where the two-way communication system is provided within areas...
-
Receivers and Couplers
Recommendations: While a system may come with only one type of receiver, a variety helps meet the needs and preferences of different users....
-
1009.8 Two-way communication
Exceptions: Two-way communication systems are not required at the landing serving each elevator or bank of elevators where the two-way communication system is provided within areas...
- Landscape Forms Inc. Central Park Conservancy Recycling System
-
2.1.1 General Description
2.1.1 General Description In an IL system, the output from an amplifier is delivered to a loop of wire placed around the circumference of a designated "listening area"....
-
Maintenance of Accessible Features
Maintenance of Accessible Features Accessible pool features must be maintained in operable, working condition so that persons with disabilities have access to the pool whenever the pool...
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the...