Section 403.5.1 covers the current ADA Standards for the clear width of walking surfaces that are part of an accessible route.
Search Results "Expected Maximum Flight Duration"
-
Clear Width: ADA Standard Section 403.5.1
-
Signal Type: ADA Standard Section 407.4.8.2.1
Section 407.4.8.2.1 covers the current ADA Standards for the signal type of audible elevator car indicators.
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum...
-
11B-812.5.4 Arrangement
Vehicle spaces installed in existing facilities shall comply with Section 11B-812.5.4 to the maximum extent feasible....
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
11B-812.5.4 Arrangement
Vehicle spaces installed in existing facilities shall comply with Section 11B-812.5.4 to the maximum extent feasible....
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum...
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
Protrusions
Objects may protrude into the space a maximum of 6 inches along the front of the space, if they are between 9 inches and 27 inches maximum above the floor....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303....
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
- Stanley Hardware 8179 Light Commercial Door Closer
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches...
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
T303.3.3 Handrail and Stanchion Non-Circular Cross Section
Handrails and stanchions with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6ΒΌ inches (160 mm) maximum, and a cross section dimension of...
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
11B-609.2.2 Non-circular cross section