When amusement rides are in the load and unload position, wheelchair spaces complying with 1002.4, amusement ride seats designed for transfer complying with 1002.5, and transfer devices...
Search Results "Door Signal Device"
-
206.2.9.2 Wheelchair Spaces, Ride Seats Designed for Transfer, and Transfer Devices
-
11B-603.2.3 Door swing
11B-603.2.3 Door swing. Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-603.2.3 Door swing
Other than the door to the accessible water closet compartment, a door in any position, may encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-603.2.3 Door swing
[2010 ADA Standards] 603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture....
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008....
- Panda S.81 All Aluminum Multi-Slide Door System Corner Detail
- Panda S.11 Lift & Slide Wood Clad Radius Pocket Door System
- Panda TS.83 Thermally Broken Multi-Slide Door System Corner Detail
- Panda S.90 All Aluminum Slim Profile Multi-Slide Door System
-
3.6. Replacement Costs
Section 3.6.2 discusses the assumptions and research regarding the rate of device replacement....
-
T503.3 Steps at Front Doorways
The walking surface on steps serving the front doorway of non-rail vehicles shall be lighted with 2 foot-candles (22 lux) minimum of illumination when the vehicle doors are open....
-
§382.127 What procedures apply to stowage of battery-powered mobility aids?
[See subsections ...]
-
§ 36.311(b)
(b)
- Norton Surface Mounted 5900 Series Low Energy Door Operator
-
Accessible Sidewalks 3: Pedestrians with Low Vision
Requires the Registered User plan or above. Login!
-
803.3 Door Swing
803.3 Door Swing. Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
Is additional latch side clearance required on the push side of doors with a forward approach when either a latch or closer (but not both) is provided?
No, latch clearance 12” minimum is required for forward approaches on the push-side of doors equipped with both a closer and a latch....
-
T503.4 Steps at Other Doorways
The walking surface on steps serving all other non-rail vehicle doorways shall be lighted at all times with 2 foot-candles (22 lux) minimum of illumination.
-
SECTION 1004 EXIT ACCESS
SECTION 1004 EXIT ACCESS
-
A4.2.1(1) Space Requirements for Wheelchairs
(1) Space Requirements for Wheelchairs. Most wheelchair users need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered head-on. If the...
-
A4.2.1(1) Space Requirements for Wheelchairs
(1) Space Requirements for Wheelchairs. Many persons who use wheelchairs need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered...
-
§ 38.73 Doorways
[See subsections ...]
-
§ 38.53 Doorways
[See subsections ...]
-
4.1.2. Upfront Costs