Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. ◼...
Search Results "Maneuvering Clearance (Alcove)"
Commonly Searched Documents
-
11B-608.1 General
-
Common Problem: Protruding Objects
The fountains shown in this photograph are recessed into an alcove to avoid the potential for injury. ...
-
11B-605.5.3 Doors
Urinal compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
IDEA Center
clearances....
- Boost Your Business - Chapter 12 - Elevators
-
Work Areas [4.1.1(3)]
Recommendations: Space for turning within the work area and interior maneuvering clearances at doors, while not required, should be considered, especially where entrapment may be a concern...
-
Wheelchair Spaces
The 33-inch minimum width for spaces provides extra width for maneuvering within a confined area....
-
11B-902.4.1 Clear floor or ground space
Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
Comparison of Single-User Toilet Room Layouts: 1A, 1B, and 1C
A lavatory with knee space can overlap the clear floor space required for the water closet provided that at least 36 inches of clearance is maintained between the side wall next to the water...
- Grants for Home Modification: 16 Resources for Homeowners with Disabilities
-
This is a great unit but it's not "recessed", it's semi-recessed.
place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space, door maneuvering...
-
UDI
Maneuvering trials were recorded using overhead video cameras....
- Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
-
Automatic Doors and Power Assisted Doors [4.13.12]
Some power-assists are activated by opening the door manually (and must meet ADAAG requirements for maneuvering clearance in 4.13.6 and opening force in 4.13.11) while others may be activated...
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
Outdoor Constructed Features
The final rule bases the size of the clear ground space at outdoor constructed features on the dimensions for maneuvering clearance at clear floor or ground spaces that are confined on all...
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
The features that make this possible are: an accessible route to and through the room; an entry door with adequate clear width, maneuvering clearance, and accessible hardware;...
-
R404 Clear Spaces (Section-by-Section Analysis)
Additional maneuvering space must be provided where an element is confined on all or part of three sides....
- Hill-Rom Viking® M Patient Lift
- Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
- Figure 608.2.2 Standard Roll-In Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
-
Minimum Clear Opening
Representatives Edwards, Frank, and Fish expressed their support for the Option One specification on minimum clearance which is consistent with the ANSI Standard....
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.