The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum....
Search Results "Emergency Call System"
-
11B-706.5 Signal-to-noise ratio
-
382.43 Must information and reservation services of carriers be accessible to individuals with hearing impairments?
., via call relay service). Such media include, for example, web sites, ticket jackets, telephone books, and print advertisements....
- Ampetronic CLS1 Wall Mount Perimeter Induction Loop Driver Hearing System
-
Section 37.75 Remanufacture of Non-Rail Vehicles and Purchase or Lease of Remanufactured Non-rail Vehicles by Public Entities Operating Fixed Route Systems
Section 37.75 Remanufacture of Non-Rail Vehicles and Purchase or Lease of Remanufactured Non-rail Vehicles by Public Entities Operating Fixed Route Systems This section tracks the statute...
- Ampetronic CLS2 Wall Mount Perimeter Induction Loop Driver Hearing System
-
10.3.1(14)
(14) Where public address systems are provided to convey information to the public in terminals, stations, or other fixed facilities, a means of conveying the same or equivalent information...
-
§ 38.23(d)(4) Orientation
In vehicles in excess of 22 feet in length, at least one securement device or system required by paragraph (a) of this section shall secure the wheelchair or mobility aid facing toward the...
-
Maintenance
Maintenance By far, the most frequent complaint about assistive listening systems is that they do not work properly and that no one at a facility knows how to operate or fix them....
-
§ 38.23(d)(6) Stowage
When not being used for securement, or when the securement area can be used by standees, the securement system shall not interfere with passenger movement, shall not present any hazardous...
-
11B-215.1 General
Exception: In existing facilities, visible alarms for fire alarm systems shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system...
-
11B-215.1 General
Exception: In existing facilities, visible alarms for fire alarm systems shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system...
-
Reservation Systems Requirements for Places of Lodging
reservation is made for an accessible guest room, the specific accessible guest room reserved must be held for the reserving customer and the room must be removed from the reservation system...
-
§ 37.73 Purchase or lease of used non-rail vehicles by public entities operating fixed route systems
[See subsections ...]
-
T213.1 General
Seats on non-rail vehicles shall comply with T213.
-
8. Revise § 37.165(b) to read as follows
8. Revise § 37.165(b) to read as follows:
-
§ 37.165 Lift and securement use
* * * * *
-
4.28.3(7)
(7) In general, no place in any room or space required to have a visual signal appliance shall be more than 50 ft (15 m) from the signal (in the horizontal plane). In large rooms and...
-
4.28.3(8)
(8) No place in common corridors or hallways in which visual alarm signalling appliances are required shall be more than 50 ft (15 m) from the signal.
-
4.28.3(6)
(6) The appliance shall be placed 80 in (2030 mm) above the highest floor level within the space or 6 in (152 mm) below the ceiling, whichever is lower.
-
8.2.1 Participants
8.2.1 Participants Forty-nine adult listeners with sensorineural hearing loss participated in this study. They were divided into six groups according the degree and configuration...
-
3.2 Microphone Location
3.2 Microphone Location There are no standards for microphone placement in live performances. The actual location appears to be a pragmatic mix composed of production...
-
5.2 Distributing Receivers
5.2 Distributing Receivers The same individual in the same physical location in a venue should be responsible for both checking in and checking out of the...
-
7. INSTALLATION
While the different ALS and venues will require different depths and ranges of competencies, all require some minimum of information if the system is to be installed correctly....
-
Mobility
Generally speaking, if a person cannot physically negotiate, use, or operate some part or element of a standard building egress system, like stairs or the door locks or latches, then that...