Our popular RollMastr 3000® bath tissue dispenser system solution delivers up to 3000 sheets of 1-ply tissue or 1500 sheets 2-ply tissue per service interval for continuous service...
Search Results "Multi-User Toilet Room"
Commonly Searched Documents
- Georgia-Pacific Rollmastr 3000® Vertical 2 Roll High Capacity Bathroom Tissue Dispenser
- Tork Elevation® High Capacity Bath Tissue Roll Dispenser, Black
- Tork Elevation® High Capacity Bath Tissue Roll Dispenser, White
-
B. Clear Width
Do bathroom doors in all guestrooms allow 32" clear passage width so persons who use wheelchairs, crutches, and other mobility aids can visit or stay in other rooms and use the bathroom?...
-
5.3.6 Entrance
The entrance to the toilet shall be level with the surrounding surface....
-
Facilities Specializing in Treating Conditions That Affect Mobility: ADA Standard Section 223.2.2
Section 223.2.2 covers scoping requirements in the current ADA Standards for facilities specializing in treating conditions that affect mobility.
-
11B-604.8.1.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
206.7.6 Guest Rooms and Residential Dwelling Units, F206.7.6 Guest Rooms and Residential Dwelling Units
206.7.6 Guest Rooms and Residential Dwelling Units F206.7.6 Guest Rooms and Residential Dwelling Units The final rule edits the references in these sections to the technical requirements...
-
H17
Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No...
-
5.3.5 Doors
Where provided, doors shall comply with ABAAS section 404. The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1.
-
Size and Arrangement [4.17.3]
[See subsections ...]
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach. The...
-
Construction Sites (§203.2)
Construction Sites (§203.2) Structures directly associated with the actual processes of construction and portable toilets used only by construction workers Examples: scaffolding...
- Horton Automatics ICU/CCU Bi-Fold/Bi-Swing™ Door System
- Horton Automatics Profiler® Smoke-Rated Telescoping ICU/CCU Sliding Door
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit?...
-
Identification of accessible features in hotels and guest rooms. (Section-by-Section Analysis)
included in the hotel's accessible guest rooms....
-
Patient Bedrooms [6.3]
[See subsections ...]
-
6.3 Patient Bedrooms
Provide accessible patient bedrooms in compliance with 4.1 through 4.35. Accessible patient bedrooms shall comply with the following:
-
6.3 PATIENT BEDROOMS
Provide accessible patient bedrooms in compliance with 4. Accessible patient bedrooms shall comply with the following:
- New Mobility
-
Platform Lifts in Transient Lodging Guest Rooms and Dwelling Units
Platform Lifts in Transient Lodging Guest Rooms and Dwelling Units....
-
703.5.5 Character Height
Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further...