(a) Clear width....
Search Results "Clear Pier Space"
-
§ 38.93(a) Clear width
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
-
1005.2 Railings
Where provided, railings, guards, or handrails shall comply with 1005.2.
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface. Exception: Where a guard complying with Chapter...
-
11B-1005.2 Railings
Where provided, railings, guards, or handrails shall comply with Section 11B-1005.2.
-
Transition Plates
Transition Plates Transition plates are sloping pedestrian walking surfaces located at the end of a gangway. Gangways are not required to have landings at the end, if transition...
-
Handrail Extensions
Handrail Extensions ADAAG addresses handrail height, diameter, and extensions provided to the end of the gangway. Other specifications regarding vertical supports may be addressed...
-
11B-1005.2 Railings
Where provided, railings, guards, or handrails shall comply with Section 11B-1005.2.
-
11B-1005.2 Railings
Where provided, railings, guards, or handrails shall comply with Section 11B-1005.2.
-
1005.2 Railings
Where provided, railings, guards, or handrails shall comply with 1005.2.
-
1005.2 Railings
1005.2 Railings. Where provided, railings, guards, or handrails shall comply with 1005.2.
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn
This data depicts the amount of space required by users of wheeled mobility devices to perform a 180-degree turn....
-
T402.6 Clear Width
The clear width of ramps and bridgeplates shall be 30 inches (760 mm) minimum....
-
Clear Tread Width
Clear Tread Width. The width of the usable trail tread and adjacent usable surface....
-
Elevators and Platform Lifts
slower elevators used for low-traffic, low-rise facilities) or platform lifts that comply with ADAAG may be used instead of gangways as part of an accessible route connecting floating piers...
-
1015.3 Viewing Space
This section requires each distinct viewing location to provide a viewing space adjacent to the clear ground space required by 1015.2 through which the point of interest is viewable....
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...
-
Obstructions
Obstructions “Obstructions” are also prohibited by TAS 604.3.2 within the required water closet clearance. An obstruction is any element that violates the protruding object...