Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
Search Results "Rear Grab Bar"
Commonly Searched Documents
-
11B-705.2 Detectable directional texture
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
-
Problem Five
The voting area and entrance to the voting area, however, are at the rear of the school and there are no designated accessible parking spaces in this area....
-
E. Restaurants and Concessions:
PSE shall continue to provide accessible tables, marked with the International Symbol for Accessibility, within the bar areas of the Red Bull Bar and Captain Morgan's Bar located in the...
-
1132A.8 Hand-activated door hardware
Latching and locking doors that are hand-activated and on an accessible route shall be operable with a single effort by lever-type hardware, panic bars, push-pull activating bars or other...
-
F234 Residential Facilities
For example, grab bars do not have to be installed during the construction of residential dwelling units if the proper reinforcement is provided to facilitate their later installation as...
-
M305.3 Standing Supports (Section-by-Section Analysis)
In the MDE NPRM preamble, the Access Board noted that it was considering adopting the cross section dimensions for grab bars from the 2004 ADA and ABA Accessibility Guidelines and applying...
-
2010 ADA Standards
For example, if this document requires “1½ inches,” avoid specifying “1½ inches plus or minus X inches. ”Where the requirement states a specified range, such as in Section 609.4 where grab...
-
104.1.1 Construction and Manufacturing Tolerances
Where the requirement states a specified range, such as in Section 609.4 where grab bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate...
-
5.4.3 Transfer Support Height for M301 and M302
The minimum height is consistent with the information provided by Midmark Corporation on examination tableside rails, and the maximum height is generally consistent with the height of grab...
-
104.1.1 Construction and Manufacturing Tolerances
Where the requirement states a specified range, such as in 609.4 where grab bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate tolerance...
-
1 - Design and drawing
Tolerances do not apply where a requirement states a range; for example, that grab bars must be installed between 33 inches and 36 inches above the finished floor....
-
Prepare different kits for different places and situations:
Grab and go kit is an easy-to-carry kit you can grab if you have to leave home (or school, workplace, etc.) in a hurry....
-
1. Making Facilities Accessible and Usable
For example: A restroom may be modified to meet standard accessibility requirements (including wider door and stalls, and grab bars in specified locations) but it may be necessary to install...
-
NSS Questions and Concerns
A revealing example: The Red Cross’s 2011 survey version asks regarding restroom grab bars: “Appropriate Grab Bars yes/no,” as compared to the DOJ questions which asks: “Is a horizontal...
-
§ 38.159(d)(4) Orientation
Where the wheelchair or mobility aid is secured facing the rear of the vehicle, a padded barrier shall be provided....
- Speakman Versatile ADA Handheld Shower System SM-5490-ADA
- Neo-Metro Commercial Contour Urinal 8944 Series
- Lynx Grills Inc. 36” Grill 1 ProSear Burner & 2 Stainless Steel Burners with Rotisserie (L600ADAR)
- Lynx Grills Inc. 30” Grill 1 ProSear Burner & 1 Stainless Steel Burner with Rotisserie (L500ADAR)
-
Clear Deck Space
The clear deck space must be a minimum of 36 inches wide and extend forward a minimum of 48 inches from a line located 12 inches behind the rear edge of the seat....
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
3) Restaurants
Contains requirements for counters and bars, access aisles, food service lines, tableware and condiment areas, raised speaker's platforms, and vending machine areas (but not controls)....