Issue 10: Braille (right side up?) Where the APS device includes the street name in Braille, care must be taken to install the signs in the correct location and...
Search Results "Elevator Hall Call Button"
-
Issue 10: Braille (right side up?)
-
707.6.1 Input Controls
At least one tactilely discernible input control shall be provided for each function. Where provided, key surfaces not on active areas of display screens, shall be raised above...
-
707.6.1 Input Controls
707.6.1 Input Controls. At least one tactilely discernible input control shall be provided for each function. Where provided, key surfaces not on active areas of display screens,...
-
11B-707.6.1 Input controls
11B-707.6.1 Input controls. At least one tactilely discernible input control shall be provided for each function. Where provided, key surfaces not on active areas of display screens,...
-
11B-707.6.1 Input controls
At least one tactilely discernible input control shall be provided for each function. Where provided, key surfaces not on active areas of display screens, shall be raised above...
-
Transfer Space: ADA Standard Section 1008.3.1.3
A transfer space complying with 305.2 and 305.3 shall be provided adjacent to the transfer platform. The 48 inch (1220 mm) long minimum dimension of the transfer space shall be...
-
Cord: ADA Standard Section 409.4.7.4
Section 409.4.7.4 covers the current ADA Standards for the emergency telephone cord in private residence elevators.
-
Platform to Hoistway Clearance: ADA Standard Section 409.4.3
Section 409.4.2 covers the ADA Standards for the required clearance between the car platform and the hoistway landing in private residence elevators.
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
Compartment: ADA Standard Section 409.4.7.3
Section 409.4.7.3 covers the current ADA Standards for the emergency communication system compartment in private residence elevators.
-
Contact: ADA Standard Section 407.3.3.2
Section 407.3.3.2 covers the current ADA Standards for the contact requirements of an elevators reopening device.
-
Duration: ADA Standard Section 407.3.3.3
Section 407.3.3.3 covers the current ADA Standards for the duration of an elevators reopening device.
-
Transfer Supports: ADA Standard Section 1008.3.1.4
At least one means of support for transferring shall be provided.
-
Transfer Supports: ADA Standard Section 1008.3.2.3
At least one means of support for transferring shall be provided. Advisory 1008.3.2.3 Transfer Supports. Transfer supports are required on transfer platforms and transfer steps to...
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. Advisory 11B-1008.3.2.3 Transfer supports. Transfer supports are required on transfer platforms and transfer...
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car.
-
11B-1008.3.1.4 Transfer supports
At least one means of support for transferring shall be provided.
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform. The 48 inch (1219 mm) long minimum dimension of the transfer...
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.