The Committee intends that such space be usable by handicapped persons, but this does not necessarily require that a turning radius be provided in every situation....
Search Results "Urinal Clear Floor Space"
-
Maneuvering Space, Adjustable Cabinetry, Fixtures and Plumbing
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
- Figure 407.4.1(b) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(e) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(d) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(c) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(a) Elevator Car Dimensions – Drawing from the U.S. Access Board
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. Advisory 11B-213.3...
-
Plumbing Fixtures and Accessories: ADA Standard Section 213.3
Section 213.3 covers scoping requirements in the current ADA Standards for plumbing fixtures and accessories.
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. Advisory 11B-213.3...
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
- Zurn Industries Floor Access Cover
-
Willoughby Industries UW-1412-WO Series Straddle Urinal Washout Type
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Willoughby Industries UW-1317-HEU Series Contoured High Efficiency Urinal
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
1002.4.1 Floor or Ground Surface
1002.4.1 Floor or Ground Surface. The floor or ground surface of wheelchair spaces shall be stable and firm....
-
Turning Space: ADA Standard Section 805.2
Turning space complying with 304 shall be provided within the room....
- American Standard Decorum 0.125 gpf High Efficiency Urinal Top Spud 1
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
The features that make this possible are: an accessible route to and through the room; an entry door with adequate clear width, maneuvering clearance, and accessible hardware;...
-
Wheelchair Storage Space: ADA Standard Section 1002.6.3
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
- PEMKO 2" Floor Plates/Safety Treads No. 190