The clear width of golf car passages shall be 48 inches (1219 mm) minimum....
Search Results "Shower Clear Floor Space"
-
11B-1006.3.1 Clear width
-
10. Shower Wand
Is there an adjustable height shower wand with at least a 60" long hose provided for persons who must shower from a seated position?...
- Cal-Royal Products Swing Clear Hinges
-
11B-809.10.2 Number of complying bathing rooms and fixtures
One bathing room and one fixture of each type within the dwelling unit shall be designed to comply with the following: Maneuvering space in toilet, bathing and shower rooms shall...
-
11B-411.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-407.4.2....
-
11B-411.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-407.4.2....
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls. ...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls....
-
11B-409.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....
-
11B-409.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall.
-
7(2)(b)(ii)
(ii) Where the door swings out, a clear space is provided within the bathroom for a person using a wheelchair or other mobility aid to position the wheelchair such that the person is allowed...
-
Boarding Pier Clearances: ADA Standard Section 1003.3.2
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier....
-
3. Folding Seat
Do the roll-in showers have a securely fastened folding seat at 17"-19" above the floor onto which persons who use wheelchairs may transfer to shower?...
-
11B-813.2.1.2 Clearance
Floor or ground surfaces of clearances shall comply with Section 11B-302. Changes in level are not permitted....
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor...
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor...
-
11B-1003.3.2 Boarding pier clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1524 mm) wide minimum and shall extend the full length of the boarding pier....
-
11B-1003.3.2 Boarding pier clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1524 mm) wide minimum and shall extend the full length of the boarding pier....
-
R404.5 Position
Unless otherwise specified, clear spaces shall be positioned for either forward or parallel approach to an element....
-
1134A.6 Showers
Showers required to be accessible shall comply with this section....
-
Clear
Clear - Unobstructed....