Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with 806.2 or residential dwelling units required...
Search Results "Portable Patient Lift"
-
206.7.6 Guest Rooms and Residential Dwelling Units
-
2. Equipment Clearances for Breast Platforms
The MDE NPRM proposed knee and toe clearance requirements for diagnostic equipment used by patients seated in wheelchairs that paralleled the knee and toe clearance requirements from the...
-
11B-223.3 Long-term care facilities
In licensed long-term care facilities, including skilled nursing facilities, intermediate care facilities and nursing homes, at least 50 percent, but no fewer than one, of each type of patient...
-
11B-223.3 Long-term care facilities
In licensed long-term care facilities, including skilled nursing facilities, intermediate care facilities and nursing homes, at least 50 percent, but no fewer than one, of each type of patient...
-
11B-223.3 Long-term care facilities
In licensed long-term care facilities, including skilled nursing facilities, intermediate care facilities and nursing homes, at least 50 percent, but no fewer than one, of each type of patient...
-
§ 382.39 Provision of services and equipment
include, as needed, the services personnel and the use of ground wheelchairs, boarding wheelchairs, on-board wheelchairs where provided in accordance with this part, and ramps or mechanical lifts...
-
Site Constraints
Platform lifts are permitted where "existing or other constraints" make ramp or elevator access "infeasible."...
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
The MDE NPRM proposed knee and toe clearance for diagnostic equipment used by patients seated in wheelchairs to allow for components in the wheelchair space which the patient could approach...
- Nova Health Products LiteRamp 5' Wheelchair and Scooter Ramp (LR5)
- Nova Health Products LiteRamp 10' Wheelchair and Scooter Ramp (LR10)
- Nova Health Products LiteRamp 4' Wheelchair and Scooter Ramp (LR4)
- Nova Health Products LiteRamp 3' Wheelchair and Scooter Ramp (LR3)
- Nova Health Products LiteRamp 2' Wheelchair and Scooter Ramp (LR2)
- Nova Health Products LiteRamp 7' Wheelchair and Scooter Ramp (LR7)
- Nova Health Products LiteRamp 6' Wheelchair and Scooter Ramp (LR6)
- Nova Health Products LiteRamp 8' Wheelchair and Scooter Ramp (LR8)
- EZ-ACCESS Suitcase Singlefold Ramp
- SafePath EZCurb™ Wheelchair Ramps - Vertical Barrier Removal
-
§ 382.40a Boarding assistance for large aircraft
(b) Carriers shall, in cooperation with the airports they serve, provide boarding assistance to individuals with disabilities using mechanical lifts, ramps, or other suitable devices that...
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum.
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3.
-
M303.2.3.3 Side Entry
Where wheelchair space entry is only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum.
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum.