In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
Search Results "One Step Entry"
-
11B-608.3.3 Alternate roll-in type shower compartments
-
Maneuvering Clearances [§404.2.4]
Clearance beyond the latch side is not required at entry doors to hospital patient rooms. ...
-
11B-804.2.1 Pass through kitchen
Pass through kitchens shall have two entries....
-
11B-804.2.1 Pass through kitchen
Pass through kitchens shall have two entries....
-
11B-407.2.3.1 Floor designation
A raised star, placed to the left of the floor designation, shall be provided on both jambs at the main entry level....
-
11B-407.2.3.1 Floor designation
A raised star, placed to the left of the floor designation, shall be provided on both jambs at the main entry level....
- Hill-Rom Uno™ 102 Patient Lift
-
Guidelines for Requirement 7
For usable kitchens, the Department adopted the Option One guidelines with one change....
-
Issue 15: Installation Errors Increase Risk
Before he could step into the street, he was stopped, and the change of the APS was explained to him....
-
T302.4 Surface Discontinuities
Steps complying with T405 shall be permitted on walking surfaces that are not part of a passenger access route....
-
Can curbs be used to indicate areas with less than 80” of vertical clearance?
Curbs may be mistaken for a step or change in level, instead of a barrier....
-
Tread Obstacles on Outdoor Recreation Access Routes
For example, a few steps at an individual campsite may not need a handrail. Where a handrail would be helpful, one handrail in the center may accommodate low-volume, two-way traffic....
-
C. Eligibility for Admission to Vocational Education Centers Based on Residence
The Office for Civil Rights will presume, subject to rebuttal, that any one or combination of the following circumstances indicates that the boundaries of a given service area are unlawfully...
-
D. INDEPENDENT LICENSED ARCHITECT
Within one hundred eighty (180) days of the entry of this Consent Decree, the County will retain an Independent Licensed Architect (“ILA”), pre-approved initially and continually approved...
-
1. Width and Depth of Wheelchair Spaces
However, the Access Board has included an additional requirement for wheelchair spaces that are entered from the front or rear and permit pass-through from one end to the other....
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
-
1.15 Stadium-style seating, stadium section, or stadium seating
Each row of stadium seating is elevated above the row immediately ahead of it and is accessed by stepped, rather than sloped, aisles....
-
Common Problems with Routes to Building Entrances
Common Problems with Routes to Building Entrances Ø The route has steps but no ramp....
-
K. Eating Areas
Eating Areas An accessible route, at least 36 inches wide and without steps or steep slopes, must be provided to and throughout the food service and eating areas of the shelter....
-
§ 38.101(b)
outside lights which, when the door is open, provide at least 1 footcandle of illumination on the station platform surface for a distance of 3 feet perpendicular to all points on the bottom step...
-
§ 37.131(a)(3) Jurisdictional boundaries
The entity shall take all practicable steps to provide paratransit service to any part of its service area....
-
§ 38.157(b)
doorway shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination on the pathway to the door for a distance of 3 feet (915 mm) to the bottom step...
-
§ 38.109 Between-car barriers
operate in a high-platform, level-boarding mode, and where between-car bellows are not provided, devices or systems shall be provided to prevent, deter or warn individuals from inadvertently stepping...
-
Treads and Risers [4.9.2], Nosings [4.9.3]
Uniformity is important not only between steps but along each step; curved stairs, where the width of each tread varies, do not meet this requirement....