Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm)...
Search Results "Multi-Bedroom Housing Unit (CBC)"
Commonly Searched Documents
-
11B-809.10.6.4 Reinforcement for grab bars
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
F245.2.3 Alterations and Additions
Where picnic units are altered or added, the requirements of F245.2 shall apply only to the picnic units that are altered or added until the number of picnic units with mobility features...
-
809.5.6 Site, Building, or Floor Entrance
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply...
-
809.5.6 Site, Building, or Floor Entrance
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply...
-
Architectural Barriers Act
Architectural Barriers Act The Architectural Barriers Act (ABA) requires that buildings and facilities that are designed, constructed, or altered with Federal funds, or leased by...
-
Requirement 7 -- Usable Kitchens and Bathrooms
[See subsections ...]
-
26.1 Q. Is a parallel approach required at the shower, as shown in Figure 7(d) of the Guidelines?
A. Yes. For a 36 x 36 shower, as shown in Figure 7(d), a person in a wheelchair would typically add a wall hung seat. Thus the parallel approach as shown in Figure 7(d) is essential...
-
1012.5 Slope
This section requires the slope of the surface of parking spaces and pull-up spaces to not be steeper than 1:48 in any direction. Where the surface is other than asphalt, concrete,...
-
§100.205(c)(3)(iv)
(iv) Usable kitchens and bathrooms such that an individual in a wheelchair can maneuver about the space.
-
(3) Usable bathrooms
., a room with only a toilet and a sink) when the powder room is the only toilet facility on the accessible level of a covered multistory dwelling unit....
-
11B-809.5.6 Site, building, or floor entrance
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply...
-
4.34.2(1)
(1) Common spaces and facilities serving individual accessible dwelling units (for example, entry walks, trash disposal facilities, and mail boxes) shall comply with 4.2 through 4.33....
-
11B-809.5.6 Site, building, or floor entrance
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply...
-
11B-809.5.6 Site, building, or floor entrance
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply...
-
F245.2.3 Alterations and Additions
This section requires picnic units that are altered or added to provide mobility features until the number of picnic units with mobility features in the picnic facility meets the minimum...
-
F245.4.2.2 Routes Within Common Use and Public Use Areas
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving picnic units with mobility...
-
Water Closet Clear Floor Space in Toilet Compartments
However, the Board has revised the specified depth in residential dwelling units where lavatories are permitted to overlap the space aside water closets....
-
809.5.6 Site, Building, or Floor Entrance
Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply...
-
11B-809.10.1 General
All toilet and bathing rooms on an accessible route within residential dwelling units with adaptable features shall comply with Sections 11B-809.7, 11B-809.8, 11B-809.10.6.4, 11B-809.10.7.3...
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
9.5.3 Accessible Sleeping Accommodations in New Construction
Accessible sleeping rooms shall be provided in conformance with the table in 9.1.2 and shall comply with 9.2 Accessible Units, Sleeping Rooms and Suites (where the items are provided)....
- Marx|Okubo Associates, Inc., Accessibility Group (ADA and FFHA)
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...