The size of this space is determined by the minimum width required for the water closet and lavatory between the side walls, the minimum wheelchair turning space, and the space required...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
Comparison of Single-User Toilet Room Layouts: 1A, 1B, and 1C
-
Additional Features of Van-Accessible Parking Spaces
The first image below shows a van-accessible space with a 60-inch minimum width access aisle. The second image shows a van-accessible space with a 96-inch minimum width access aisle....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Where do I measure for a handrail extension?
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs. 505.10.2 Top Extension at Stairs....
- Pilot Rock CSL-6 and CSL-8 Car Stop
-
4. Breast Platform Adjustability
This manufacturer also recommended requiring a minimum range of travel for the breast platform instead of a specific minimum and maximum height....
- Landscape Forms Inc. Petoskey Bench Collection
- FBD Partnership Four Flavors Frozen Beverage Dispenser
- Willoughby Industries ETW-1490-FM-HC Floor Mount Wall Outlet Rear Mounted ADA Blow Out Type Flush Toilet
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....
-
R404.3 Size
Clear spaces shall be 760 mm (2.5 ft) minimum by 1220 mm (4.0 ft) minimum....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
UDI
All dimensions were taken to the extremes of the equipment including any object attached to the device like a ventilator....
-
11B-403.5.1 Clear width
are 48 inches (1219 mm) long minimum and 36 inches (914 mm) wide minimum. 2. ...
-
Self Contained, Closed Products - Side Reach Range
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
1005.3.2 Extended Ground or Deck Surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
Technically Infeasible
structural frame; or because other existing physical or site constraints prohibit modification or addition of elements, spaces, or features that are in full and strict compliance with the minimum...
-
Break Out Opening: ADA Standard Section 404.3.6
Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates.