The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
Search Results "Exam Room"
-
11B-809.10.6.2 Slope
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
Sleeping Areas: ADA Standard Section 806.2.3
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
Verify Framing
clearances/landings at doors. 11B-404 Distance between doors in series. 11B-404.2.6 Grab bar backing in toilet/shower rooms...
-
Verify Framing
clearances/landings at doors. 11B-404 Distance between doors in series. 11B-404.2.6 Grab bar backing in toilet/shower rooms...
- Harris Communication SafeAwake Fire Alarm Aid with Bed Shaker
-
Section 36.406(c) Places of Lodging (Section-by-Section Analysis)
The proposed rule, in the definitions section, clarifies that a covered "place of lodging" is a facility that provides guest rooms for sleeping for stays that are primarily short-term in...
-
Directional visual sign vs. room identification tactile sign
The arrow appears to indicate that this specific sign is a directional sign pointing toward the location of an accessible toilet room. ...
-
M101.2 Application (Section-by-Section Analysis)
In the NPRM the Access Board proposed that the MDE Standards would be applied to diagnostic equipment based on the patient position the equipment is designed to support....
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25...
-
5.1.3 Transfer Surface Low Height Options for M301 and M302
5.1.3 Transfer Surface Low Height Options for M301 and M302 The Committee did not agree on a final low height recommendation. Rationale for final recommendation (more detail...
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height
-
5.1.2 Transfer Surface High Height
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches.
-
5.1.1 Transfer Surface Height Adjustability
5.1.1 Transfer Surface Height Adjustability. The transfer surface should have an adjustable height in small virtually continuous increments.
-
9.5.2(1)(a)
(a) The provisions of 9.5.3 and 9.1.5 shall apply to sleeping rooms and beds....
-
603.2.1 Turning Space
Turning space complying with 304 shall be provided within the room....