Doors shall be permitted to swing into turning spaces....
Search Results "Elevator Car Door"
-
11B-304.4 Door swing
-
Type: ADA Standard Section 409.4.7.1
Section 409.4.7.1: covers the current ADA Standards for the type of elevator emergency communication systems in private residence elevators.
-
Elevated Play Component
Elevated Play Components An elevated play component is a play component that is approached above or below grade and is part of a composite play structure. ...
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides, elevators...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides, elevators...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides, elevators...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides, elevators...
-
A4.13.9 Door Hardware
Some disabled persons must push against a door with their chair or walker to open it....
-
Door Maneuvering Clearance
Section 404.2.4 addresses maneuvering clearances at manual doors, doorways, and gates....
-
17.1 Q. Is it correct that only the exterior side of the main entry door of covered multifamily dwellings must meet the ANSI requirements?
The exterior side of the main entry door is part of the public and common use areas and therefore must meet ANSI A117.1 1986 specifications for doors....
-
11B-411.2.1.1 Location
Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted, or mounted...
-
11B-411.2.1.1 Location
Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted, or mounted...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides, elevators...
-
Opening Force [§404.2.9]
to fully open a door, not the initial force needed to overcome the door’s seal resulting from unequal pressure....
-
11B-407.2.1.5 Signals
Existing elevators shall not be required to comply with 407.2.1.5....
-
11B-407.2.1.5 Signals
Existing elevators shall not be required to comply with 407.2.1.5....
-
11B-409.1 General
They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be automatic. Advisory 11B-409.1 General....
-
11B-409.1 General
They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be automatic. Advisory 11B-409.1 General....
-
Opening Force
Section 404.2.9 addresses the opening force of doors and gates....
-
A4.13.9 DOOR HARDWARE
Some disabled persons must push against a door with their chair or walker to open it....
-
11B-411.1 General
Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1....
-
11B-411.1 General
Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1....