FIGURE 11B-608.2.2 ‡‡ STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE...
Search Results "Roll-In Access"
Commonly Searched Documents
-
11B-608.2.2.1 Clearance
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
F224.2 Guest Rooms with Mobility Features
) depending on number of guest rooms] Table 224.2 Guest Rooms with Mobility Features Total Number of Guest Rooms Provided Minimum Number of Required Rooms Without Roll-in...
-
H. Men's Spa and Fitness Center Locker Room
Men's Spa and Fitness Center Locker Room: (1) Defendants will install a vertical, self-operating lift in the Men's Spa whirlpool in order to permit access for persons with disabilities...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
224.2 Guest Rooms with Mobility Features
Table 224.2 Guest Rooms with Mobility Features Minimum Number of Required Rooms Without Roll-in Showers Minimum Number of Required Rooms...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
11B-608.5.3 Alternate roll-in type shower compartments
11B-608.5.3 Alternate roll-in type shower compartments....
-
Example of a Single-User Bathroom (with Roll-in Shower)
Example of a Single-User Bathroom (with Roll-in Shower) Clear space required at any fixture can overlap required clear floor spaces, turning space, and door maneuvering space....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303....
- Access Board: Accessible Bathing Facilities Scoping
-
Marking: ADA Standard Section 502.3.3
Section 502.3.3 covers the current ADA Standards for marking access aisles.
-
Width: ADA Standard Section 502.3.1
Section 502.3.1 covers the current ADA Standards for the required width of access aisles.
-
3. Folding Seat
Do the roll-in showers have a securely fastened folding seat at 17"-19" above the floor onto which persons who use wheelchairs may transfer to shower?...
-
Length: ADA Standard Section 502.3.2
Section 502.3.2 covers the current ADA Standards for the length of access aisles.
-
Size and Clearances [4.21.2]
When a seat is provided in a roll-in shower, it must be a folding seat. Recommendation: Twelve inches of additional clear floor space at the seat will facilitate side transfers....
-
11B-224.2 Guest rooms with mobility features
In transient lodging facilities, guest rooms with mobility features complying with Section 11B-806.2 shall be provided in accordance with Table 11B-224.2, as follows. [2010 ADAS]...
-
11B-224.2 Guest rooms with mobility features
In transient lodging facilities, guest rooms with mobility features complying with Section 11B-806.2 shall be provided in accordance with Table 11B-224.2, as follows. [2010 ADAS]...
-
Location: ADA Standard Section 502.3.4
Section 502.3.4 covers the current ADA Standards for the required location of access aisles.
-
A4.21.1 GENERAL
Shower stalls that are 36 in by 36 in (915 mm by 915 mm) wide provide additional safety to people who have difficulty maintaining balance because all grab bars and walls are within...
-
11B-608.2.2.1 Clearance
11B-608.2.2.1 Clearance. A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010...