Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
Search Results "Roll-In Access"
Commonly Searched Documents
-
11B-608.7 Thresholds
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
5.1.2 Level or Sloped Entry
Camp shelters providing roll-in access shall have a level or sloped entry that complies with the FSORAG Outdoor Recreation Access Route technical provisions if the camp shelter is in a campground...
-
Shower Compartment Seats: ADA Standard Section 610.3
Section 610.3 covers the current ADA Standards for shower compartment seats.
-
Alternate Roll-in Showers
Specifications are provided for alternate roll-in showers, including their size and the location of entries (608.2.3)....
-
608.2.2 Standard Roll-In Type Shower Compartments
608.2.2 Standard Roll-In Type Shower Compartments....
-
1014.1 General
The technical requirements address the entrance to camp shelters (1014.2), including transfer access (1014.2.1) and roll-in access (1014.2.2); and the floor within camp shelters (1014.3)...
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
11B-608.2.2 Standard roll-in type shower compartments....
-
Toilet and Bathing Facilities: ADA Standard Section 806.2.4
In addition, required roll-in shower compartments shall comply with 608.2.2 or 608.2.3....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
11B-224.8.2 More than 50-bed facilities
When separate shower facilities are provided for men and women, at least one roll-in shower shall be provided for each group....
-
Guest Rooms with Mobility Features: ADA Standard Section 224.2
Section 224.2 covers scoping requirements in the current ADA Standards for transient lodging guest rooms with mobility features.
-
Clearance: ADA Standard Section 608.2.2.1
Section 608.2.2.1 covers the current ADA Standards for the clearances of standard roll-in type shower compartments.
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
1. Number of Roll-in Showers
If there are more than 50 guestrooms/suites in the facility, are the proper number of accessible rooms with roll-in showers provided per table 9.1.2 below....
-
11B-806.2.4 Toilet and bathing facilities
In addition, required roll-in shower compartments shall comply with Section 11B-608.2.2 or 11B- 608.2.3....
-
Thresholds: ADA Standard Section 608.7
Section 608.7 covers the current ADA Standards for thresholds in shower compartments.
-
608.2.3 Alternate Roll-In Type Shower Compartments
608.2.3 Alternate Roll-In Type Shower Compartments....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
11B-608.2.3 Alternate roll-in type shower compartments
11B-608.2.3 Alternate roll-in type shower compartments....