Handrail extensions are not required where gangways and transition plates connect and both are provided with handrails....
Search Results "Push Plate"
-
Handrail Extensions
-
T402.11 Gaps
When ramps or bridgeplates are deployed for boarding and alighting, gaps between the ramp or bridgeplate surface and floor of non-rail vehicles shall not permit passage of a sphere...
-
Location: ADA Standard Section 703.4.2
EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices....
-
§ 38.83(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
- Activar Hiawatha 5-1/2P Series Pull with Matching Push Plate
-
11B-703.4.2 Location
where sign installation locations identified in Section 11B-703.4.2 are obstructed or otherwise unavailable for sign installation, signs with tactile characters shall be permitted on the push...
-
11B-703.4.2 Location
where sign installation locations identified in Section 11B-703.4.2 are obstructed or otherwise unavailable for sign installation, signs with tactile characters shall be permitted on the push...
-
§ 38.95(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
§ 38.125(c)(6)(ii) Exception
Ramps or bridge plates which are attached to, and deployed from, station platforms are permitted in lieu of car devices provided they meet the displacement requirements of paragraph (c)(...
-
T402.6 Clear Width
The clear width of ramps and bridgeplates shall be 30 inches (760 mm) minimum.
-
T402.1 General
Ramps and bridgeplates shall comply with T402. Ramps and bridgeplates shall be permitted to fold or telescope.
-
T402.2 Design Load
Ramps and bridgeplates 30 inches (760 mm) or more in length shall be designed to support a load of 600 pounds (273 kg) minimum, placed at the centroid of the ramp distributed over an...
-
T402.8 Running Slope
The maximum running slope of ramps and bridgeplates shall comply with T402.8.1 or T402.8.2.
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is...
-
§ 38.83(c)(6) Attachment
(6) Attachment—
-
§ 38.83(c)(5) Slope
Ramps or bridge plates shall have the least slope practicable....
-
§ 38.95(c)(6)(i) Requirement
When in use for boarding or alighting, the ramp or bridge plate shall be attached to the vehicle, or otherwise prevented from moving such that it is not subject to displacement when loading...
-
§ 38.83(c)(3) Ramp threshold
The transition from roadway or station platform and the transition from vehicle floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
Cross Slope
Cross Slope The cross slopes of gangways, transition plates and floating piers that are part of an accessible route must be designed and constructed not to exceed a maximum of 2 percent...
- SOSS Door Hardware UltraLatch Installation Video
- SOSS Door Hardware Invisible Hinge Installation Video
- SOSS Door Hardware UltraLatch Demonstration Video
-
§ 38.125(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
§ 38.125(c)(6)(i) Requirement
When in use for boarding or alighting, the ramp or bridge plate shall be attached to the vehicle, or otherwise prevented from moving such that it is not subject to displacement when loading...