Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
Search Results "Nurse Call System"
Commonly Searched Documents
-
11B-411.2.1.5.1 Size
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background.
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background.
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
Two-Way Communication Systems: ADA Standard Section 708
[See subsections ...]
-
11B-706 Assistive listening systems
[See subsections ...]
-
17. Q. What about "911" calls? How are those made accessible to people with speech or hearing disabilities?
Individuals with hearing and speech disabilities must have direct access to "911" or similar emergency telephone services, meaning that emergency response centers must be equipped to receive calls...
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. Advisory 11B-407.2.1.3 Clear floor or ground space....
-
Infrared Systems
Infrared Systems These systems use invisible (infrared) light beams to carry information from a transmitter connected to a public address system or microphone to special portable receivers...
-
11B-411.2.1 Hall call consoles
SECTION TITLE NOTES 11B-411.2.1 11B-411.2.1.2 11B-411.2.1.2.2 Hall call consoles....
-
FM Systems
FM Systems FM systems use a short-range radio transmitter which converts sound to a radio signal sent to small FM radios tuned to the same channel usually worn around the neck....
-
11B-411.2.1.3.4 Position
Display screens and touch screens shall be positioned so glare is reduced on the screen. Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical...
-
Hardwired Systems
Hardwired Systems Hardwired systems incorporate a direct wire link between the sound source and the coupler....
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-411.2.1.4.2 Security or access controls
Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility....
-
11B-411.2.1.4.2 Security or access controls
Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility....
-
11B-411.2.1.4.2 Security or access controls
Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility....
-
11B-708 Two-way communication systems
[See subsections ...]
-
Recognizing TTY Calls/Treating Silent, Open Lines as Potential TTY Calls
All call takers must be able to recognize and handle TTY calls properly. There are three types of TTY calls a call taker may receive....
-
11B-411.2.1.3.1 Keypad call console arrangement
Where keypad call consoles are provided, the display screen shall be located directly above the keypad....