The finished floor shall extend to the wall under the lavatory....
Search Results "Lavatory"
-
11B-809.10.8.3 Cabinets
-
11B-809.10.8.3 Cabinets
The finished floor shall extend to the wall under the lavatory....
-
5. Clear floor space
Clear floor space is needed for a forward approach to the lavatory....
- Whitehall Mfg. Demo of a Variety of Innovative Healthcare products
-
4.19.2 HEIGHT AND CLEARANCES
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finished floor....
-
4.19.2 Height and Clearances
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finish floor....
-
4.19.4 EXPOSED PIPES AND SURFACES
Hot water and drain pipes under lavatories shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories....
-
4.19.4 Exposed Pipes and Surfaces
Hot water and drain pipes under lavatories shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories....
-
382.65 What are the requirements concerning on-board wheelchairs?
In aircraft with more than 60 passenger seats, carriers must provide an onboard wheelchair if the aircraft has an accessible lavatory....
-
1134A.8, Item 4.1
The space beneath the lavatory shall be left clear and unobstructed;...
-
1134A.8, Item 4.1
The space beneath the lavatory shall be left clear and unobstructed;...
-
Exposed Pipes and Surfaces [4.19.4]
Exposed Pipes and Surfaces [4.19.4] To prevent burns, hot water pipes and drain pipes under lavatories must be insulated or otherwise configured to protect against contact....
-
1134A.8, Item 4.2
Any cabinet beneath the lavatory shall be removable without the use of specialized knowledge or specialized tools; or,...
-
1134A.8, Item 4.2
Any cabinet beneath the lavatory shall be removable without the use of specialized knowledge or specialized tools; or...
-
H9
Are the drain and hot water pipes for this lavatory insulated or otherwise configured to protect against contact? [ADA Standards § 4.19.4] Yes No...
-
11B-306.3.3 Minimum required depth
At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth of 8 inches (203 mm...
-
11B-306.3.3 Minimum required depth
Exceptions: At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
11B-306.3.3 Minimum required depth
Exceptions: At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture....
-
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section....
-
11B-809.10.5.1 Clear floor space
The area under a lavatory, located at the control end of the tub, shall be permitted to encroach on the clear floor space provided the lavatory is 19 inches (483 mm) maximum in depth, and...
-
11B-809.10.5.1 Clear floor space
The area under a lavatory, located at the control end of the tub, shall be permitted to encroach on the clear floor space provided the lavatory is 19 inches (483 mm) maximum in depth, and...