At interior doors maneuvering clearances shall be 42 inches (1067 mm) minimum in length on the both (sic) sides of the door measured perpendicular to the face of the door in the closed position...
Search Results "Interior"
-
11B-809.8.3 Door maneuvering clearance.
-
11B-404.2.9 Door and gate opening force
Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum. 3. ...
-
11B-404.2.9 Door and gate opening force
Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum. 3....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: Interior hinged doors and gates: 5 pounds (22.2 N) maximum....
-
1132A.3, Item 4
4. A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable.
-
Signage
Comment and Question by Tom Williams: Along with the discussion about wayfinding and signage, it brings out the issue of contrast and tactile signs and so on. One of the things that...
-
A4.13.11 Door Opening Force
Although most people with disabilities can exert at least 5 lbf (22.2N), both pushing and pulling from a stationary position, a few people with severe disabilities cannot exert 3 lbf...
-
A4.13.11 DOOR OPENING FORCE
Although most people with disabilities can exert at least 5 lbf (22.2N), both pushing and pulling from a stationary position, a few people with severe disabilities cannot exert even...
-
Opening Force [§404.2.9]
Opening Force [§404.2.9] The maximum 5 lbf opening force applies to all accessible doors and gates except: fire doors (minimum opening force allowed by...
-
1132A.3, Item 4
4. A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable.
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2....
- Access Board: Door Opening Force
- The Centre for Excellence in Universal Design
-
Sec. 469.102. Procedure for Submitting Plans and Specifications
[See subsections ...]
- Institute for Design and Disability (IDD) (Ireland)
- Design Guidelines for the Visual Environment
-
F210.1 General
Interior and exterior stairs that are part of a means of egress shall comply with 504. EXCEPTIONS: 1....
-
210.1 General
Interior and exterior stairs that are part of a means of egress shall comply with 504. EXCEPTIONS: 1....
-
210.1 General
Interior and exterior stairs that are part of a means of egress shall comply with 504. EXCEPTIONS: 1....
-
210 Stairways
1991 Standards for Accessible Design 2010 Standards for Accessible Design What’s New/Different 4.1.3(4) Interior...
-
Pricilla Rogers, Ph.D., Center on Vision Loss, American Foundation for the Blind
., standard] for green buildings; provides for 10% less interior lighting wattage than ASHRAE [90.1]....
-
X. Designated Agencies
Department of Interior: Lands and natural resources, including parks and recreation, water and waste management, environmental protection, energy, historic and cultural preservation, and...